Impact of multiplicative noise removal on digital volume correlation-based optical coherence elastography
Digital volume correlation-based optical coherence elastography (DVC-based OCE) may easily suffer from multiplicative speckle noise of optical coherence tomography (OCT) imaging, which can introduce non-negligible calculation errors. In this study, Hamilton-Jacobi partial differential equations were adopted for multiplicative noise removal of OCT images and the impact of multiplicative noise removal on DVC-based OCE was investigated. Several deformation conditions, including static, sub-pixel translation, uniform compression and non-uniform deformation, were tested. Results showed that multiplicative noise removal can suppress the maximum noise-induced error to less than 0.15 pixels in static tests. A more precise sub-pixel translation with an accuracy of 0.6 pixels was obtained. For uniform compression, multiplicative noise removal can extend the strain upper limit to 0.116 with an error less than 15% and a correlation value higher than 0.8. It also worked better in non-uniform deformation with more reliable calculation points. These findings provide a way to improve the measurement accuracy of the DVC-based OCE method by removing multiplicative noise on OCT images. • Hamilton-Jacobi partial differential equations were adopted on multiplicative noise removal of OCT images. • Deformation conditions were tested for multiplicative noise removal on optical coherence elastography. • Multiplicative noise removal was proven to be effective on digital volume correlation-based optical coherence elastography.
Authors
- Runxin Fang (ORCID: https://orcid.org/0000-0003-0152-5928)
- Han Yu (ORCID: https://orcid.org/0009-0002-9896-9639)
- Jiaqiu Wang (ORCID: https://orcid.org/0000-0001-7710-3508)
- Hujin Xie (ORCID: https://orcid.org/0000-0001-8339-0523)
- Zhiyong Li (ORCID: https://orcid.org/0000-0002-6814-9165)
- Hao Wu (ORCID: https://orcid.org/0000-0001-5738-4015)
- Zhengduo Zhu (ORCID: https://orcid.org/0009-0002-8620-2086)
Institutions
- Ningbo University (CN)
- Queensland University of Technology (AU)
- London South Bank University (GB)
- Jiangsu Institute of Metrology (CN)
- Southeast University (CN)
Publication Details
- Journal
- Optics and Lasers in Engineering
- Published
- 2025-05-26
- DOI
- https://doi.org/10.1016/j.optlaseng.2025.109097
- Citations
- 5
- Primary Topic
- Optical Coherence Tomography Applications
- Type
- article
- Field-Weighted Citation Impact
- 3.37
Funders
- National Natural Science Foundation of China
- Australian Research Council