A 96 dB Input Dynamic Range Galvanic Skin Response Readout IC With 3.5 pA<sub>rms</sub> Input-Referred Noise for Mental Stress Monitoring

This paper presents a low-noise, low-power galvanic skin response (GSR) sensing circuit capable of simultaneously measuring skin conductance level (SCL) and skin conductance response (SCR) for psychological stress monitoring. The circuit incorporates second-order sub-ten-hertz filters that suppresses out-of-band interference and a programmable gain amplifier (PGA) to accommodate signals of varying magnitudes. Additionally, a dynamic range adjustment mechanism optimizes the primary amplifier's operating range based on real-time SCL readings. The design achieves a 96.4 dB dynamic range with an input-referred noise of only 3.47 pA<sub>rms</sub> within 0.5-5 Hz under optimal conditions. These advancements significantly enhance measurement accuracy and robustness for wearable stress monitoring and real-time biofeedback applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2025-05-26
DOI
https://doi.org/10.1109/tbcas.2025.3573614
Citations
1
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 96 dB Input Dynamic Range Galvanic Skin Response Readout IC With 3.5 pArms Input-Referred Noise for Mental Stress Monitoring

Lin Chou, Yu‐Te Liao, Kun‐Ju Tsai, Yi-Jie Lin
1 citations
IEEE Transactions on Biomedical Circuits and Systems
Analog and Mixed-Signal Circuit Design
0.67
article

A 96 dB Input Dynamic Range Galvanic Skin Response Readout IC With 3.5 pArms Input-Referred Noise for Mental Stress Monitoring

Lin Chou, Yu‐Te Liao, Kun‐Ju Tsai, Yi-Jie Lin
article en
1 citations

Abstract

This paper presents a low-noise, low-power galvanic skin response (GSR) sensing circuit capable of simultaneously measuring skin conductance level (SCL) and skin conductance response (SCR) for psychological stress monitoring. The circuit incorporates second-order sub-ten-hertz filters that suppresses out-of-band interference and a programmable gain amplifier (PGA) to accommodate signals of varying magnitudes. Additionally, a dynamic range adjustment mechanism optimizes the primary amplifier's operating range based on real-time SCL readings. The design achieves a 96.4 dB dynamic range with an input-referred noise of only 3.47 pA<sub>rms</sub> within 0.5-5 Hz under optimal conditions. These advancements significantly enhance measurement accuracy and robustness for wearable stress monitoring and real-time biofeedback applications.

IEEE Transactions on Biomedical Circuits and SystemsVol. 19(5)
National Yang Ming Chiao Tung University (TW), Industrial Technology Research Institute (TW)
Openalex Percentile: Top 31%
Analog and Mixed-Signal Circuit Design
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 96 dB Input Dynamic Range Galvanic Skin Response Readout IC With 3.5 pA<sub>rms</sub> Input-Referred Noise for Mental Stress Monitoring — Lin Chou, Yu‐Te Liao, et al. · IEEE Transactions on Biomedical Circuits and Systems (2025) | TGRS Research Map | TGRS