A Novel Robotic Guiding Sheath With Variable Stiffness Capability Based on Conductive Graphene and Thermoplastic Polymer

In robot-assisted endoscopic procedures, a guiding sheath must be flexibly advanced through anatomic paths via natural orifices, while maintaining sufficient rigidity to serve as a base for the surgical instruments used in dexterous diagnostic and therapeutic tasks. Therefore, developing a guiding sheath with the capacity of both flexible access and variable stiffness is imperative and challenging. To address these challenges, we have developed a novel robotic guiding sheath. Its stiffness can be managed using the innovatively-manufactured variable stiffness coating layer (VSCL), which has a thickness of only 1 mm and is composed of polycaprolactone (PCL) and conductive graphene. An active water heating and cooling mechanism was designed to regulate the temperature of the VSCL, thereby controlling the stiffness of the guiding sheath. Through detailed performance evaluation, the guiding sheath achieved a fixed-end bending stiffness gain of 25.76 and a mid-span bending stiffness gain of 25.01, reaching a fixed-end bending stiffness of 739.63 N/m and a mid-span bending stiffness of 5779.33 N/m. The fast switching between the rigid and flexible states was realized with switching times of 6.5 s (from rigid state to flexible state) and 10.0 s (from flexible state to rigid state). The sheath was also validated with phantom and ex-vivo experiments. The capability of this guiding sheath to traverse the tortuous digestive tract in a flexible state was proved. Additionally, the guiding sheath in a rigid state can significantly improve instrument manipulation stability during the ex-vivo trials. The experimental results demonstrated the potential clinical value of this system.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2025-05-26
DOI
https://doi.org/10.1109/tmrb.2025.3573412
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Robotic Guiding Sheath With Variable Stiffness Capability Based on Conductive Graphene and Thermoplastic Polymer

Yuesheng Qu, Chengyu Zhang, Chi Zhang, Siyang Zuo
IEEE Transactions on Medical Robotics and Bionics
Advanced Sensor and Energy Harvesting Materials
article

A Novel Robotic Guiding Sheath With Variable Stiffness Capability Based on Conductive Graphene and Thermoplastic Polymer

Yuesheng Qu, Chengyu Zhang, Chi Zhang, Siyang Zuo
article en

Abstract

In robot-assisted endoscopic procedures, a guiding sheath must be flexibly advanced through anatomic paths via natural orifices, while maintaining sufficient rigidity to serve as a base for the surgical instruments used in dexterous diagnostic and therapeutic tasks. Therefore, developing a guiding sheath with the capacity of both flexible access and variable stiffness is imperative and challenging. To address these challenges, we have developed a novel robotic guiding sheath. Its stiffness can be managed using the innovatively-manufactured variable stiffness coating layer (VSCL), which has a thickness of only 1 mm and is composed of polycaprolactone (PCL) and conductive graphene. An active water heating and cooling mechanism was designed to regulate the temperature of the VSCL, thereby controlling the stiffness of the guiding sheath. Through detailed performance evaluation, the guiding sheath achieved a fixed-end bending stiffness gain of 25.76 and a mid-span bending stiffness gain of 25.01, reaching a fixed-end bending stiffness of 739.63 N/m and a mid-span bending stiffness of 5779.33 N/m. The fast switching between the rigid and flexible states was realized with switching times of 6.5 s (from rigid state to flexible state) and 10.0 s (from flexible state to rigid state). The sheath was also validated with phantom and ex-vivo experiments. The capability of this guiding sheath to traverse the tortuous digestive tract in a flexible state was proved. Additionally, the guiding sheath in a rigid state can significantly improve instrument manipulation stability during the ex-vivo trials. The experimental results demonstrated the potential clinical value of this system.

IEEE Transactions on Medical Robotics and BionicsVol. 7(3)
Tianjin University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 89%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.