Cyclic Testing of T-Shaped Concrete-Filled Composite Plate Shear Wall Having Bolted Splices

This paper presents results from cyclic testing of a large-scale T-shaped composite plate shear walls concrete-filled (C-PSW/CF) specimen having bolted splices. The horizontal splice was designed to develop approximately 60% of the faceplate yield strength in tension, while vertical splices were designed on the basis of slip-resistance, using steel component and composite section approaches. A proposed simplified method was used to calculate the target flexural strength of the horizontal splice to develop the bearing strength of 2.4 and 3.0dtFu. The tested wall achieved the target flexural strength and maintained at least 80% of peak strength until 2.4% positive drift and −4.3% negative drift, with no slip observed in vertical splices. This research demonstrated that the behavior of a bolted C-PSW/CF under axial and cyclic lateral loads is satisfactory for the intended purposes, and that designing horizontal bolted splices governed by bearing strength results in a ductile response.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2025-05-27
DOI
https://doi.org/10.1061/jsendh.steng-14501
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cyclic Testing of T-Shaped Concrete-Filled Composite Plate Shear Wall Having Bolted Splices

Michel Bruneau, Jia‐Hau Liu
Journal of Structural Engineering
Structural Load-Bearing Analysis
article

Cyclic Testing of T-Shaped Concrete-Filled Composite Plate Shear Wall Having Bolted Splices

Michel Bruneau, Jia‐Hau Liu
article en

Abstract

This paper presents results from cyclic testing of a large-scale T-shaped composite plate shear walls concrete-filled (C-PSW/CF) specimen having bolted splices. The horizontal splice was designed to develop approximately 60% of the faceplate yield strength in tension, while vertical splices were designed on the basis of slip-resistance, using steel component and composite section approaches. A proposed simplified method was used to calculate the target flexural strength of the horizontal splice to develop the bearing strength of 2.4 and 3.0dtFu. The tested wall achieved the target flexural strength and maintained at least 80% of peak strength until 2.4% positive drift and −4.3% negative drift, with no slip observed in vertical splices. This research demonstrated that the behavior of a bolted C-PSW/CF under axial and cyclic lateral loads is satisfactory for the intended purposes, and that designing horizontal bolted splices governed by bearing strength results in a ductile response.

Journal of Structural EngineeringVol. 151(8)
University at Buffalo, State University of New York (US)
Sustainable cities and communities
Openalex Percentile: Top 88%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.