2× Thru De-Embedding Challenges

Fixture de-embedding is a method used to remove unnecessary effects introduced by test fixture in measurement, allowing for the accurate extraction of S-parameters for the device under test. Among the known fixture de-embedding techniques, 2× Thru de-embedding is one of the most widely used methods, both commercially and in scientific research, due to its efficiency and ease of implementation. By reducing the number of measurements required, 2× Thru de-embedding maintains its popularity compared to traditional methods. The method is standardized by the “IEEE Standard for Electrical Characterization of Printed Circuit Board and Related Interconnects at Frequencies up to 50 GHz”, which defines the design requirements for test fixtures and requires a long transmission line in the center of the 2× Thru structure. The presented paper discusses cases when 2× Thru violates the norms given by the standard, namely when the transmission line in the center of the 2× Thru structure is too short, as a result of which it is obtained that the discontinuity in the fixture does not vanish before it reaches middle point of the structure. The paper analyzes these cases, and it is accepted that even in the case of such devices, using existing de-embedding tools, it is possible to obtain correct left and right fixtures.

Authors

Institutions

Publication Details

Journal
Journal of Electronics and Electrical Engineering
Published
2025-05-26
DOI
https://doi.org/10.37256/jeee.4120256598
Citations
1
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

2× Thru De-Embedding Challenges

Salome Oniani
1 citations
Journal of Electronics and Electrical Engineering
Microwave and Dielectric Measurement Techniques
0.73
article

2× Thru De-Embedding Challenges

Salome Oniani
article en
1 citations

Abstract

Fixture de-embedding is a method used to remove unnecessary effects introduced by test fixture in measurement, allowing for the accurate extraction of S-parameters for the device under test. Among the known fixture de-embedding techniques, 2× Thru de-embedding is one of the most widely used methods, both commercially and in scientific research, due to its efficiency and ease of implementation. By reducing the number of measurements required, 2× Thru de-embedding maintains its popularity compared to traditional methods. The method is standardized by the “IEEE Standard for Electrical Characterization of Printed Circuit Board and Related Interconnects at Frequencies up to 50 GHz”, which defines the design requirements for test fixtures and requires a long transmission line in the center of the 2× Thru structure. The presented paper discusses cases when 2× Thru violates the norms given by the standard, namely when the transmission line in the center of the 2× Thru structure is too short, as a result of which it is obtained that the discontinuity in the fixture does not vanish before it reaches middle point of the structure. The paper analyzes these cases, and it is accepted that even in the case of such devices, using existing de-embedding tools, it is possible to obtain correct left and right fixtures.

Journal of Electronics and Electrical Engineering
Georgian Technical University (GE)
National Science Foundation, Shota Rustaveli National Science Foundation
Openalex Percentile: Top 28%
Microwave and Dielectric Measurement Techniques
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.