Human osteoblast response to uncemented knee implant surface structures and osteoclast formation in vitro

Early bone ingrowth and minimal resorption ensure rigid fixation in uncemented total knee replacements. Trabecular titanium-aluminum-vanadium (Ti6Al4V) and hydroxyapatite (HA)-coated vacuum-plasma-sprayed (VPS) titanium with varying porosities and HA-coating thicknesses, have been developed to enhance fixation, though bone cellular response remains largely unknown. This study evaluated osteoblast responses to trabecular Ti6Al4V and three VPS titanium surfaces with 20%-40% or 30%-70% porosity and HA coatings of 60, 80, or 90 µm. Human primary osteoblasts were seeded and cultured for 29 days, to assess seeding efficiency, viability, metabolic activity, alkaline phosphatase activity, and the effect of osteoblast-released factors in conditioned medium during the last 4 days of culture on osteoclast formation. VPS-HA groups were first compared individually; when no differences were found, data were pooled for comparison with the trabecular group. Osteoblast seeding efficiency, viability, metabolic activity, and alkaline phosphatase activity were similar between VPS-HA surfaces. Moreover, osteoblast-conditioned medium did not affect osteoclast formation. Osteoblast seeding efficiency and viability were similar between the pooled VPS-HA and trabecular surface. Compared to the pooled VPS-HA, the trabecular surface increased osteoblast metabolic (1.5-2.7-fold) and alkaline phosphatase activity (6.5-15.2-fold). Osteoblast-conditioned medium reduced osteoclast formation (2.1-3.4-fold) on trabecular compared to the pooled VPS-HA surface. In conclusion, these findings show that VPS-HA surfaces with various porosities and HA-coating thicknesses similarly affect osteoblast and osteoclast responses, while trabecular surfaces enhance osteoblast responsiveness and inhibit osteoclast formation. These results might help to further improve early stability and reduce long-term loosening risk in uncemented knee replacements.

Authors

Institutions

Publication Details

Journal
Journal of Biomaterials Applications
Published
2025-05-25
DOI
https://doi.org/10.1177/08853282251346324
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Human osteoblast response to uncemented knee implant surface structures and osteoclast formation in vitro

Behrouz Zandieh‐Doulabi, Bart G. C. W. Pijls, Jenneke Klein‐Nulend, Raymond Puijk et al.
2 links
Journal of Biomaterials Applications
Orthopaedic implants and arthroplasty
article

Human osteoblast response to uncemented knee implant surface structures and osteoclast formation in vitro

Behrouz Zandieh‐Doulabi, Bart G. C. W. Pijls, Jenneke Klein‐Nulend, Raymond Puijk, Peter A. Nolte, Wendy J.A.M. Runderkamp
article en

Abstract

Early bone ingrowth and minimal resorption ensure rigid fixation in uncemented total knee replacements. Trabecular titanium-aluminum-vanadium (Ti6Al4V) and hydroxyapatite (HA)-coated vacuum-plasma-sprayed (VPS) titanium with varying porosities and HA-coating thicknesses, have been developed to enhance fixation, though bone cellular response remains largely unknown. This study evaluated osteoblast responses to trabecular Ti6Al4V and three VPS titanium surfaces with 20%-40% or 30%-70% porosity and HA coatings of 60, 80, or 90 µm. Human primary osteoblasts were seeded and cultured for 29 days, to assess seeding efficiency, viability, metabolic activity, alkaline phosphatase activity, and the effect of osteoblast-released factors in conditioned medium during the last 4 days of culture on osteoclast formation. VPS-HA groups were first compared individually; when no differences were found, data were pooled for comparison with the trabecular group. Osteoblast seeding efficiency, viability, metabolic activity, and alkaline phosphatase activity were similar between VPS-HA surfaces. Moreover, osteoblast-conditioned medium did not affect osteoclast formation. Osteoblast seeding efficiency and viability were similar between the pooled VPS-HA and trabecular surface. Compared to the pooled VPS-HA, the trabecular surface increased osteoblast metabolic (1.5-2.7-fold) and alkaline phosphatase activity (6.5-15.2-fold). Osteoblast-conditioned medium reduced osteoclast formation (2.1-3.4-fold) on trabecular compared to the pooled VPS-HA surface. In conclusion, these findings show that VPS-HA surfaces with various porosities and HA-coating thicknesses similarly affect osteoblast and osteoclast responses, while trabecular surfaces enhance osteoblast responsiveness and inhibit osteoclast formation. These results might help to further improve early stability and reduce long-term loosening risk in uncemented knee replacements.

Journal of Biomaterials ApplicationsVol. 40(5)
Leiden University Medical Center (NL), Academic Center for Dentistry Amsterdam (NL), Spaarne Ziekenhuis (NL), Spaarne Gasthuis (NL), Vrije Universiteit Amsterdam (NL), University of Amsterdam (NL)
Amsterdam University Medical Centers
Openalex Percentile: Top 80%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.