An Electrochemical Detection of Malathion Pesticide Using Cu Electrode and Enhanced by Machine Learning

Abstract The present work demonstrates the development of an economical and user‐friendly “copper rods” sensor for detecting malathion. Differential pulse voltammetry (DPV) was performed to observe the inhibition ratio at various concentrations of malathion, which increases with an increase in malathion concentration. The parameters like pH and accumulation time were optimized at 4 pH and 18 min, respectively, corresponding to the maximum inhibition ratio (Δ I / I 0 ). The electrochemical sensor had a relative standard deviation (RSD) of up to 7.05 % ( n = 3), which indicated reproducible results. The regression line showed linearity over a range of 25–200 parts per billion (ppb), and the limit of quantification (LOQ) was as low as 25 ppb (75.67 nM). The developed sensor was sensitive and selective, with a limit of detection (LOD) as low as 1 ppb (3.03 nM). The selectivity of the sensor was also studied by adding Pb(NO 3 ) 2 , Zn(NO 3 ) 2 , and NiCl 2 to a solution of fixed malathion concentration, and minimal interference was observed. The sensor's functionality was validated using an unknown concentration of malathion with 96 % and 106 % recovery, respectively. The sensitivity of this proposed sensor was 0.0165 µA ppb −1 . Quantification of malathion was also facilitated using partial least squares (PLS) algorithms utilizing the sensory measurements of the malathion‐contaminated samples. PLS is a statistical machine learning algorithm that has been used here to develop a predictor for unknown malathion concentration using the DPV current signatures of the contaminated solution with a nominal error of 5.0 %.

Authors

Institutions

Publication Details

Journal
Chemical Engineering & Technology
Published
2025-05-25
DOI
https://doi.org/10.1002/ceat.70036
Citations
1
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Electrochemical Detection of Malathion Pesticide Using Cu Electrode and Enhanced by Machine Learning

Madhusree Kundu, Adhidesh S. Kumawat, Ashirbad Khuntia, Kamalakanta Mahapatra
1 citations
Chemical Engineering & Technology
Spectroscopy and Chemometric Analyses
0.75
article

An Electrochemical Detection of Malathion Pesticide Using Cu Electrode and Enhanced by Machine Learning

Madhusree Kundu, Adhidesh S. Kumawat, Ashirbad Khuntia, Kamalakanta Mahapatra
article en
1 citations

Abstract

Abstract The present work demonstrates the development of an economical and user‐friendly “copper rods” sensor for detecting malathion. Differential pulse voltammetry (DPV) was performed to observe the inhibition ratio at various concentrations of malathion, which increases with an increase in malathion concentration. The parameters like pH and accumulation time were optimized at 4 pH and 18 min, respectively, corresponding to the maximum inhibition ratio (Δ I / I 0 ). The electrochemical sensor had a relative standard deviation (RSD) of up to 7.05 % ( n = 3), which indicated reproducible results. The regression line showed linearity over a range of 25–200 parts per billion (ppb), and the limit of quantification (LOQ) was as low as 25 ppb (75.67 nM). The developed sensor was sensitive and selective, with a limit of detection (LOD) as low as 1 ppb (3.03 nM). The selectivity of the sensor was also studied by adding Pb(NO 3 ) 2 , Zn(NO 3 ) 2 , and NiCl 2 to a solution of fixed malathion concentration, and minimal interference was observed. The sensor's functionality was validated using an unknown concentration of malathion with 96 % and 106 % recovery, respectively. The sensitivity of this proposed sensor was 0.0165 µA ppb −1 . Quantification of malathion was also facilitated using partial least squares (PLS) algorithms utilizing the sensory measurements of the malathion‐contaminated samples. PLS is a statistical machine learning algorithm that has been used here to develop a predictor for unknown malathion concentration using the DPV current signatures of the contaminated solution with a nominal error of 5.0 %.

Chemical Engineering & TechnologyVol. 48(6)
National Institute of Technology Rourkela (IN), Centurion University of Technology and Management (IN)
Openalex Percentile: Top 32%
Spectroscopy and Chemometric Analyses
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.