Accuracy Verification of a Computed Tomography-Based Navigation System for Total Hip Arthroplasty in Severe Hip Dysplasia: A Simulation Study Using 3D-Printed Bone Models of Crowe Types II, III, and IV

<i>Background and Objective</i>: The use of computed tomography (CT)-based navigation systems has been shown to improve surgical accuracy in total hip arthroplasty. However, there is limited literature available about the application of CT-based navigation systems in severe hip dysplasia. This study aimed to evaluate the accuracy of a CT-based navigation system in patients with severe hip dysplasia using three-dimensional (3D)-printed bone models. <i>Methods</i>: 3D-printed bone models were generated from CT data of patients with severe hip dysplasia (Crowe type II, 10 hips; type III, 10 hips; and type IV, 10 hips). The accuracy of automatic segmentation, success rate, point-matching accuracy across different registration methods, and deviation values at reference points after registration were assessed. <i>Results</i>: For the combined cohort of Crowe II, III, and IV cases (<i>n</i> = 30), the Dice Similarity Coefficient and Jaccard Index were 0.99 ± 0.01 and 0.98 ± 0.02, respectively. These values indicate a high level of segmentation accuracy. The "Matching with true and false acetabulum + iliac crest" method achieved a 100% success rate across all groups, with mean deviations of 0.08 ± 0.28 mm in the Crowe II group, 0.12 ± 0.33 mm in the Crowe III group, and 0.14 ± 0.50 mm in the Crowe IV group (<i>p</i> = 0.572). In the Crowe IV group, the anterior superior iliac spine deviation was significantly lower using the "Matching with true and false acetabulum + iliac crest" method compared to the "Matching with true and false acetabulum" method (0.28 ± 0.49 mm vs. 3.29 ± 2.56 mm, <i>p</i> < 0.05). <i>Conclusions</i>: This study demonstrated the high accuracy of automatic AI-based segmentation, with a Dice Similarity Coefficient of 0.99 ± 0.01 and a Jaccard Index of 0.98 ± 0.02 in the combined cohort of Crowe type II, III, and IV cases (<i>n</i> = 30). The matching success rate was 100%, with additional points on the iliac crest, which improved matching accuracy and reduced deviations, depending on the case.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-05-24
DOI
https://doi.org/10.3390/medicina61060973
Citations
2
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Verification of a Computed Tomography-Based Navigation System for Total Hip Arthroplasty in Severe Hip Dysplasia: A Simulation Study Using 3D-Printed Bone Models of Crowe Types II, III, and IV

Yasutaka Masada, Toshifumi Ozaki, Tomoko Tetsunaga, Yuki Okazaki et al.
2 citations
Medicina
Orthopaedic implants and arthroplasty
4.01
article

Accuracy Verification of a Computed Tomography-Based Navigation System for Total Hip Arthroplasty in Severe Hip Dysplasia: A Simulation Study Using 3D-Printed Bone Models of Crowe Types II, III, and IV

Yasutaka Masada, Toshifumi Ozaki, Tomoko Tetsunaga, Yuki Okazaki, Ryuichiro Okuda, Tomohiro Inoue, Tomonori Tetsunaga, Kazuki Yamada, Takashi Koura
article en
2 citations

Abstract

<i>Background and Objective</i>: The use of computed tomography (CT)-based navigation systems has been shown to improve surgical accuracy in total hip arthroplasty. However, there is limited literature available about the application of CT-based navigation systems in severe hip dysplasia. This study aimed to evaluate the accuracy of a CT-based navigation system in patients with severe hip dysplasia using three-dimensional (3D)-printed bone models. <i>Methods</i>: 3D-printed bone models were generated from CT data of patients with severe hip dysplasia (Crowe type II, 10 hips; type III, 10 hips; and type IV, 10 hips). The accuracy of automatic segmentation, success rate, point-matching accuracy across different registration methods, and deviation values at reference points after registration were assessed. <i>Results</i>: For the combined cohort of Crowe II, III, and IV cases (<i>n</i> = 30), the Dice Similarity Coefficient and Jaccard Index were 0.99 ± 0.01 and 0.98 ± 0.02, respectively. These values indicate a high level of segmentation accuracy. The "Matching with true and false acetabulum + iliac crest" method achieved a 100% success rate across all groups, with mean deviations of 0.08 ± 0.28 mm in the Crowe II group, 0.12 ± 0.33 mm in the Crowe III group, and 0.14 ± 0.50 mm in the Crowe IV group (<i>p</i> = 0.572). In the Crowe IV group, the anterior superior iliac spine deviation was significantly lower using the "Matching with true and false acetabulum + iliac crest" method compared to the "Matching with true and false acetabulum" method (0.28 ± 0.49 mm vs. 3.29 ± 2.56 mm, <i>p</i> < 0.05). <i>Conclusions</i>: This study demonstrated the high accuracy of automatic AI-based segmentation, with a Dice Similarity Coefficient of 0.99 ± 0.01 and a Jaccard Index of 0.98 ± 0.02 in the combined cohort of Crowe type II, III, and IV cases (<i>n</i> = 30). The matching success rate was 100%, with additional points on the iliac crest, which improved matching accuracy and reduced deviations, depending on the case.

MedicinaVol. 61(6)
Okayama University (JP), Okayama University Hospital (JP)
Openalex Percentile: Top 7%
Orthopaedic implants and arthroplasty
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.