Performance Analysis of Artificial Intelligence Models for Classification of Transmission Line Losses

Conventional approaches to analyzing power losses in electrical transmission networks have largely emphasized generic power loss minimization through the integration of loss-reducing devices such as shunt capacitors. However, achieving optimal power loss minimization requires a more data-driven and intelligent approach that transcends traditional methods. This study presents a novel classification-based methodology for detecting and analyzing transmission line losses using real-world data from the Ikorodu–Sagamu 132 kV double-circuit line in Nigeria, selected for its dense concentration of high-voltage consumers. Twelve (12) transmission lines were examined, and the collected data were subjected to comprehensive preprocessing, feature engineering, and modeling. The classification capabilities of advanced deep learning models—Long Short-Term Memory (LSTM), Bidirectional Long Short-Term Memory (BiLSTM), and Gated Recurrent Unit (GRU)—were explored through six experimental scenarios: LSTM, LSTM with Attention Mechanism (LSTM-AM), BiLSTM, GRU, LSTM-BiLSTM, and LSTM-GRU. These models were implemented using the Python programming environment and evaluated using standard performance metrics, including accuracy, precision, recall, F1-score, support, and confusion matrices. Statistical analysis revealed significant variability in transmission losses, particularly in lines such as I1, Ps, Ogy, and ED, which exhibited high standard deviations. The LSTM-AM model achieved the highest classification accuracy of 83.84%, outperforming both standalone and hybrid models. In contrast, BiLSTM yielded the lowest performance. The findings demonstrate that while standalone models like GRU and LSTM are effective, the incorporation of attention mechanisms into LSTM architecture enhances classification accuracy. This study provides a compelling case for employing deep learning-based classification techniques in intelligent power loss classification across transmission networks. It also supports the realization of SDG 7 by aiming to provide access to reliable, affordable, and sustainable energy for all.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-25
DOI
https://doi.org/10.3390/en18112742
Primary Topic
Electricity Theft Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of Artificial Intelligence Models for Classification of Transmission Line Losses

Abraham Amole, Olamide O. Olusanya, Ignatius K. Okakwu, Stephen Oladipo et al.
Energies
Electricity Theft Detection Techniques
article

Performance Analysis of Artificial Intelligence Models for Classification of Transmission Line Losses

Abraham Amole, Olamide O. Olusanya, Ignatius K. Okakwu, Stephen Oladipo, Ibrahim A. Giwa, Oluwagbemiga E. Ajiboye
article en

Abstract

Conventional approaches to analyzing power losses in electrical transmission networks have largely emphasized generic power loss minimization through the integration of loss-reducing devices such as shunt capacitors. However, achieving optimal power loss minimization requires a more data-driven and intelligent approach that transcends traditional methods. This study presents a novel classification-based methodology for detecting and analyzing transmission line losses using real-world data from the Ikorodu–Sagamu 132 kV double-circuit line in Nigeria, selected for its dense concentration of high-voltage consumers. Twelve (12) transmission lines were examined, and the collected data were subjected to comprehensive preprocessing, feature engineering, and modeling. The classification capabilities of advanced deep learning models—Long Short-Term Memory (LSTM), Bidirectional Long Short-Term Memory (BiLSTM), and Gated Recurrent Unit (GRU)—were explored through six experimental scenarios: LSTM, LSTM with Attention Mechanism (LSTM-AM), BiLSTM, GRU, LSTM-BiLSTM, and LSTM-GRU. These models were implemented using the Python programming environment and evaluated using standard performance metrics, including accuracy, precision, recall, F1-score, support, and confusion matrices. Statistical analysis revealed significant variability in transmission losses, particularly in lines such as I1, Ps, Ogy, and ED, which exhibited high standard deviations. The LSTM-AM model achieved the highest classification accuracy of 83.84%, outperforming both standalone and hybrid models. In contrast, BiLSTM yielded the lowest performance. The findings demonstrate that while standalone models like GRU and LSTM are effective, the incorporation of attention mechanisms into LSTM architecture enhances classification accuracy. This study provides a compelling case for employing deep learning-based classification techniques in intelligent power loss classification across transmission networks. It also supports the realization of SDG 7 by aiming to provide access to reliable, affordable, and sustainable energy for all.

EnergiesVol. 18(11)
Bells University of Technology (NG), University of Johannesburg (ZA), Olabisi Onabanjo University (NG)
Openalex Percentile: Top 90%
Electricity Theft Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.