Influence of Abutment Geometry on Zirconia Crown Retention: An In Vitro Study

<b>Background/Objectives</b>: This in vitro study investigated the retention of three different geometrical designs of short titanium base (Ti-base) abutments used in implant-supported zirconia crowns. The advent of digital technology has facilitated the integration of Ti-base abutments into implant dentistry by improving time efficiency, precision, and patient comfort. <b>Methods</b>: Three types of short Ti-base abutments were evaluated: Geo SRN multibase<sup>®</sup> (Group A), Herilink<sup>®</sup> (Group B), and TS Link<sup>®</sup> (Group C), each with a height of 4 mm and gingival height of 1 mm (n = 20 per group). Zirconia crowns (LUXEN<sup>®</sup> Smile S2, DentalMax, Republic of Korea) were modified for the testing setup and fabricated using CAD/CAM technology, then bonded to the abutments with RelyX<sup>®</sup> Luting 2 resin-modified glass ionomer cement. Pull-out tests were conducted at a crosshead speed of 1 mm/min to assess retention. <b>Results</b>: One-way ANOVA and post hoc Tukey tests revealed significant differences in retention values among the different abutment shapes (<i>p</i> < 0.05). The mean retention forces were 194.65 N for Group A, 241.33 N for Group C, and 360.20 N for Group B. <b>Conclusions</b>: The geometrical design of Ti-base short abutments significantly affects the retention of CAD/CAM zirconia crowns, with hexagonal shapes (Group B) demonstrating superior retention. Clinically, selecting an abutment design with enhanced mechanical retention may improve the long-term success of implant-supported restorations.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-05-24
DOI
https://doi.org/10.3390/ma18112469
Citations
2
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
3.58
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Abutment Geometry on Zirconia Crown Retention: An In Vitro Study

Sang-Ho Eom, Jae‐Sung Kwon, Jae Hoon Lee, Bayandelger Davaatseren
2 citations
Materials
Dental Implant Techniques and Outcomes
3.58
article

Influence of Abutment Geometry on Zirconia Crown Retention: An In Vitro Study

Sang-Ho Eom, Jae‐Sung Kwon, Jae Hoon Lee, Bayandelger Davaatseren
article en
2 citations

Abstract

<b>Background/Objectives</b>: This in vitro study investigated the retention of three different geometrical designs of short titanium base (Ti-base) abutments used in implant-supported zirconia crowns. The advent of digital technology has facilitated the integration of Ti-base abutments into implant dentistry by improving time efficiency, precision, and patient comfort. <b>Methods</b>: Three types of short Ti-base abutments were evaluated: Geo SRN multibase<sup>®</sup> (Group A), Herilink<sup>®</sup> (Group B), and TS Link<sup>®</sup> (Group C), each with a height of 4 mm and gingival height of 1 mm (n = 20 per group). Zirconia crowns (LUXEN<sup>®</sup> Smile S2, DentalMax, Republic of Korea) were modified for the testing setup and fabricated using CAD/CAM technology, then bonded to the abutments with RelyX<sup>®</sup> Luting 2 resin-modified glass ionomer cement. Pull-out tests were conducted at a crosshead speed of 1 mm/min to assess retention. <b>Results</b>: One-way ANOVA and post hoc Tukey tests revealed significant differences in retention values among the different abutment shapes (<i>p</i> < 0.05). The mean retention forces were 194.65 N for Group A, 241.33 N for Group C, and 360.20 N for Group B. <b>Conclusions</b>: The geometrical design of Ti-base short abutments significantly affects the retention of CAD/CAM zirconia crowns, with hexagonal shapes (Group B) demonstrating superior retention. Clinically, selecting an abutment design with enhanced mechanical retention may improve the long-term success of implant-supported restorations.

MaterialsVol. 18(11)
Yonsei University (KR), Yonsei University Dental Hospital (KR), Yonsei University College of Dentistry
Openalex Percentile: Top 8%
Dental Implant Techniques and Outcomes
3.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Abutment Geometry on Zirconia Crown Retention: An In Vitro Study — Sang-Ho Eom, Jae‐Sung Kwon, et al. · Materials (2025) | TGRS Research Map | TGRS