Echocardiographic and Hemodynamic Effects of Intraaortic Balloon Pump in Patients with Cardiogenic Shock on Veno-Arterial Extracorporeal Membrane Oxygenation

We investigated echocardiographic and hemodynamic effects of intraaortic balloon pump (IABP) in 26 patients with cardiogenic shock on veno-arterial membrane oxygenation (VA ECMO). Our study demonstrated an 8.1% increase in left ventricular velocity time integral (<i>p</i> = 0.023) without reduction in left ventricular diameters and 4.7% decrease in right ventricular end diastolic base diameter (<i>p</i> = 0.05) when using IABP 1:1 mode compared to no augmentation. This was associated with a 3.2% decrease in heart rate (<i>p</i> < 0.001) and a 3.0% increase in mixed venous oxygen saturation (<i>p</i> = 0.057). Since the magnitude of the documented favorable changes is rather small, the clinical relevance of concomitant IABP in patients with cardiogenic shock on VA ECMO remains questionable.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-24
DOI
https://doi.org/10.3390/jcm14113687
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Echocardiographic and Hemodynamic Effects of Intraaortic Balloon Pump in Patients with Cardiogenic Shock on Veno-Arterial Extracorporeal Membrane Oxygenation

Tomaž Goslar, Misa Fister, Peter Radšel, Marko Noc
Journal of Clinical Medicine
Mechanical Circulatory Support Devices
article

Echocardiographic and Hemodynamic Effects of Intraaortic Balloon Pump in Patients with Cardiogenic Shock on Veno-Arterial Extracorporeal Membrane Oxygenation

Tomaž Goslar, Misa Fister, Peter Radšel, Marko Noc
article en

Abstract

We investigated echocardiographic and hemodynamic effects of intraaortic balloon pump (IABP) in 26 patients with cardiogenic shock on veno-arterial membrane oxygenation (VA ECMO). Our study demonstrated an 8.1% increase in left ventricular velocity time integral (<i>p</i> = 0.023) without reduction in left ventricular diameters and 4.7% decrease in right ventricular end diastolic base diameter (<i>p</i> = 0.05) when using IABP 1:1 mode compared to no augmentation. This was associated with a 3.2% decrease in heart rate (<i>p</i> < 0.001) and a 3.0% increase in mixed venous oxygen saturation (<i>p</i> = 0.057). Since the magnitude of the documented favorable changes is rather small, the clinical relevance of concomitant IABP in patients with cardiogenic shock on VA ECMO remains questionable.

Journal of Clinical MedicineVol. 14(11)
University of Ljubljana (SI), Ljubljana University Medical Centre (SI)
Javna Agencija za Raziskovalno Dejavnost RS
Good health and well-being
Openalex Percentile: Top 89%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Echocardiographic and Hemodynamic Effects of Intraaortic Balloon Pump in Patients with Cardiogenic Shock on Veno-Arterial Extracorporeal Membrane Oxygenation — Tomaž Goslar, Misa Fister, et al. · Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS