Influence of Increased Intra-Abdominal Pressure on the Validity of Ultrasound-Derived Inferior Vena Cava Measurements for Estimating Central Venous Pressure

<b>Background:</b> Ultrasound-based assessment of the inferior vena cava (IVC) is a widely used, non-invasive tool for estimating volume status and central venous pressure (CVP) in critically ill patients. However, elevated intra-abdominal pressure (IAP) may distort IVC measurements, reducing the accuracy of CVP estimation. This study aimed to quantify the effect of varying IAP on IVC diameters and evaluate the accuracy of ultrasound-based CVP predictions under such conditions. <b>Methods:</b> A prospective study was conducted including two groups of adult critically ill patients: one with spontaneously elevated IAP due to ascites (<i>n</i> = 36), undergoing stepwise pressure reduction via paracentesis, and one with normal baseline IAP (<i>n</i> = 30), undergoing stepwise pressure elevation using an abdominal belt with an inflatable balloon. End-inspiratory and end-expiratory IVC diameters and CVP were repeatedly measured at different IAP levels. Agreement between predicted and measured CVP was assessed using Gwet's agreement coefficient, and a correction model for IVC diameters was developed based on IAP categories. <b>Results:</b> Increasing IAP led to a progressive reduction in both inspiratory and expiratory IVC diameters, while CVP showed no consistent trend. Predictive accuracy declined with rising IAP, with Gwet's agreement coefficient decreasing from 0.851 (95 percent confidence interval: 0.750-0.952) at normal pressure to 0.392 (95 percent confidence interval: 0.141-0.642) at IAP above 25 mmHg. Applying the correction model improved prediction accuracy, with Gwet's agreement coefficient increasing to 0.749 (95 percent confidence interval: 0.589-0.908) at the highest IAP category. <b>Conclusions:</b> Elevated IAP significantly alters IVC diameters and reduces the reliability of ultrasound-based CVP estimation. A correction model based on IAP improves predictive accuracy and may enhance volume assessment in critically ill patients. Further validation is warranted.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-24
DOI
https://doi.org/10.3390/jcm14113684
Citations
3
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
6.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Increased Intra-Abdominal Pressure on the Validity of Ultrasound-Derived Inferior Vena Cava Measurements for Estimating Central Venous Pressure

Ela Ćurčić, Vladimir Trkulja, Toni Ivičić, Luka Bielen et al.
3 citations
Journal of Clinical Medicine
Hemodynamic Monitoring and Therapy
6.02
article

Influence of Increased Intra-Abdominal Pressure on the Validity of Ultrasound-Derived Inferior Vena Cava Measurements for Estimating Central Venous Pressure

Ela Ćurčić, Vladimir Trkulja, Toni Ivičić, Luka Bielen, Radovan Radonić, Sara Šundalić, Mia Rora
article en
3 citations

Abstract

<b>Background:</b> Ultrasound-based assessment of the inferior vena cava (IVC) is a widely used, non-invasive tool for estimating volume status and central venous pressure (CVP) in critically ill patients. However, elevated intra-abdominal pressure (IAP) may distort IVC measurements, reducing the accuracy of CVP estimation. This study aimed to quantify the effect of varying IAP on IVC diameters and evaluate the accuracy of ultrasound-based CVP predictions under such conditions. <b>Methods:</b> A prospective study was conducted including two groups of adult critically ill patients: one with spontaneously elevated IAP due to ascites (<i>n</i> = 36), undergoing stepwise pressure reduction via paracentesis, and one with normal baseline IAP (<i>n</i> = 30), undergoing stepwise pressure elevation using an abdominal belt with an inflatable balloon. End-inspiratory and end-expiratory IVC diameters and CVP were repeatedly measured at different IAP levels. Agreement between predicted and measured CVP was assessed using Gwet's agreement coefficient, and a correction model for IVC diameters was developed based on IAP categories. <b>Results:</b> Increasing IAP led to a progressive reduction in both inspiratory and expiratory IVC diameters, while CVP showed no consistent trend. Predictive accuracy declined with rising IAP, with Gwet's agreement coefficient decreasing from 0.851 (95 percent confidence interval: 0.750-0.952) at normal pressure to 0.392 (95 percent confidence interval: 0.141-0.642) at IAP above 25 mmHg. Applying the correction model improved prediction accuracy, with Gwet's agreement coefficient increasing to 0.749 (95 percent confidence interval: 0.589-0.908) at the highest IAP category. <b>Conclusions:</b> Elevated IAP significantly alters IVC diameters and reduces the reliability of ultrasound-based CVP estimation. A correction model based on IAP improves predictive accuracy and may enhance volume assessment in critically ill patients. Further validation is warranted.

Journal of Clinical MedicineVol. 14(11)
University Hospital Centre Zagreb (HR), University of Zagreb (HR)
Sveučilište u Zagrebu
Openalex Percentile: Top 4%
Hemodynamic Monitoring and Therapy
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.