Unidimensional neutron shielding model for VARSKIN+

A simple, one-dimensional neutron shielding model that can account for energy loss of neutrons traversing various materials (currently water and polyethylene, with a general framework for easy expansion to other materials) is developed and validated for use in the multipurpose dose calculation code VARSKIN+. Verification of this model is performed using Monte Carlo methods to provide an energy response comparison, and directly using empirically derived dose response curves for water shielding and a more realistic scenario of a source in a paraffin-filled barrel. Doses calculated using VARSKIN+ are within 20%-100% of the rigorous results, depending on complexity, and can be calculated within minutes, as opposed to hours for Monte Carlo results. This provides a good starting point for neutron shielding studies, before more computationally intensive tools are employed to calculate a more accurate dose value.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-05-25
DOI
https://doi.org/10.1093/rpd/ncaf052
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unidimensional neutron shielding model for VARSKIN+

Charlotte Rose, Zane Tucker
Radiation Protection Dosimetry
Nuclear Physics and Applications
article

Unidimensional neutron shielding model for VARSKIN+

Charlotte Rose, Zane Tucker
article en

Abstract

A simple, one-dimensional neutron shielding model that can account for energy loss of neutrons traversing various materials (currently water and polyethylene, with a general framework for easy expansion to other materials) is developed and validated for use in the multipurpose dose calculation code VARSKIN+. Verification of this model is performed using Monte Carlo methods to provide an energy response comparison, and directly using empirically derived dose response curves for water shielding and a more realistic scenario of a source in a paraffin-filled barrel. Doses calculated using VARSKIN+ are within 20%-100% of the rigorous results, depending on complexity, and can be calculated within minutes, as opposed to hours for Monte Carlo results. This provides a good starting point for neutron shielding studies, before more computationally intensive tools are employed to calculate a more accurate dose value.

Radiation Protection DosimetryVol. 201(9)
Corvallis Environmental Center (US), Renaissance Services (United States) (US)
U.S. Nuclear Regulatory Commission
Affordable and clean energy
Openalex Percentile: Top 83%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.