Comparison of parametric methods with quantum mechanics based models to estimate Clog <i>P</i> values

Abstract The logarithm of octanol-water partition coefficient (log P ) is estimated by means of six parametric methods (iLOGP, XLOGP3, WLOGP, MLOGP, SILICOS-IT, OBLogP) and six quantum mechanics (QM) based models. QM models comprise DFT functional choice (B3LYP, M06-X, PBE0, including the xTB parametrization variant), implicit solvent model choice (IEFPCM, SMD, or ALPB), and basis set quality in DFT calculations (6-31G* and 6-311++G**). Several statistics are evaluated to compare Clog P estimates to experimentally measured dataset of 36 molecules picked from Meylan and Howard J. Pharm. Sci. 84 (1995) 83—92. ChemmineR cluster analysis has been performed to confirm structural diversity of molecules in the employed molecular dataset. XLOGP3 performance is the best among all the methods used, while SMD based DFT models showed a clearly competitive results with the remaining parametric methods irrespective of DFT functional or basis set quality.

Authors

Institutions

Publication Details

Journal
Acta Chimica Slovaca
Published
2025-01-01
DOI
https://doi.org/10.2478/acs-2025-0002
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of parametric methods with quantum mechanics based models to estimate Clog P values

Dávid Zajaček, Matej Uhliar, Andrej Hlinčík, Lukáš Bučinský
Acta Chimica Slovaca
Metabolomics and Mass Spectrometry Studies
article

Comparison of parametric methods with quantum mechanics based models to estimate Clog P values

Dávid Zajaček, Matej Uhliar, Andrej Hlinčík, Lukáš Bučinský
article en

Abstract

Abstract The logarithm of octanol-water partition coefficient (log P ) is estimated by means of six parametric methods (iLOGP, XLOGP3, WLOGP, MLOGP, SILICOS-IT, OBLogP) and six quantum mechanics (QM) based models. QM models comprise DFT functional choice (B3LYP, M06-X, PBE0, including the xTB parametrization variant), implicit solvent model choice (IEFPCM, SMD, or ALPB), and basis set quality in DFT calculations (6-31G* and 6-311++G**). Several statistics are evaluated to compare Clog P estimates to experimentally measured dataset of 36 molecules picked from Meylan and Howard J. Pharm. Sci. 84 (1995) 83—92. ChemmineR cluster analysis has been performed to confirm structural diversity of molecules in the employed molecular dataset. XLOGP3 performance is the best among all the methods used, while SMD based DFT models showed a clearly competitive results with the remaining parametric methods irrespective of DFT functional or basis set quality.

Acta Chimica SlovacaVol. 18(1)
Slovak University of Technology in Bratislava (SK)
Openalex Percentile: Top 90%
Metabolomics and Mass Spectrometry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.