A contrastive learning network for reducing metal artifacts in post-surgical knee computed tomography

Metallic knee implants can impair diagnostic accuracy in post-surgical computed tomography (CT) imaging. This study develops a novel deep neural network, contrastive learning metal artifact reduction (CLMAR), designed to reduce metal artifacts in knee CT scans following internal fixation or total knee arthroplasty. Our retrospective study encompassed knee CT images from 66 patients, reconstructed using bone and soft tissue algorithms. We generated a simulated artifact dataset (SAD) comprising 1200 artifact-free slices for quantitative analysis, employing metrics such as peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and structural similarity index measure (SSIM). Additionally, a real artifact dataset (RAD) with 100 slices containing real artifacts was created for qualitative assessment through a five-point physician manual scoring system. Quantitative analysis on the SAD demonstrated that CLMAR outperformed other MAR methods across different reconstruction algorithms and display windows (bone / soft tissue), achieving superior performance in PSNR (34.72 ± 2.56 / 26.97 ± 2.26), RMSE (28.71 ± 8.18 / 18.54 ± 4.77), and SSIM (0.9592 ± 0.0252 / 0.9272 ± 0.0295), with statistically significant improvements from initial artifact images ( P < 0.001). Qualitatively, CLMAR received the highest physician rating on the RAD (3.87 ± 0.96 / 3.45 ± 0.91), indicating better artifact reduction compared to existing methods. CLMAR effectively reduces metal artifacts in post-surgical knee CT images, improving both training and inference efficiency. This enhancement increases image readability, enabling physicians to interpret post-surgical knee CT with greater accuracy. CLMAR significantly reduces metal artifacts in post-surgical knee CT scans, enhancing diagnostic accuracy and image readability. • CLMAR significantly reduces metal artifacts in post-surgical knee CT. • CLMAR outperforms other methods in quantitative and qualitative results. • CLMAR achieves superior metrics on simulated and real artifact datasets. • CLMAR shows fine generalization across different reconstruction methods. • CLMAR produces visually superior images with enhanced diagnostic quality.

Authors

Institutions

Publication Details

Journal
Radiation Physics and Chemistry
Published
2025-05-24
DOI
https://doi.org/10.1016/j.radphyschem.2025.112971
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A contrastive learning network for reducing metal artifacts in post-surgical knee computed tomography

Hong Zhou, Langtao Zhou, Yifeng Peng, Yinghong Li et al.
Radiation Physics and Chemistry
Advanced X-ray and CT Imaging
article

A contrastive learning network for reducing metal artifacts in post-surgical knee computed tomography

Hong Zhou, Langtao Zhou, Yifeng Peng, Yinghong Li, Jia Deng
article en

Abstract

Metallic knee implants can impair diagnostic accuracy in post-surgical computed tomography (CT) imaging. This study develops a novel deep neural network, contrastive learning metal artifact reduction (CLMAR), designed to reduce metal artifacts in knee CT scans following internal fixation or total knee arthroplasty. Our retrospective study encompassed knee CT images from 66 patients, reconstructed using bone and soft tissue algorithms. We generated a simulated artifact dataset (SAD) comprising 1200 artifact-free slices for quantitative analysis, employing metrics such as peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and structural similarity index measure (SSIM). Additionally, a real artifact dataset (RAD) with 100 slices containing real artifacts was created for qualitative assessment through a five-point physician manual scoring system. Quantitative analysis on the SAD demonstrated that CLMAR outperformed other MAR methods across different reconstruction algorithms and display windows (bone / soft tissue), achieving superior performance in PSNR (34.72 ± 2.56 / 26.97 ± 2.26), RMSE (28.71 ± 8.18 / 18.54 ± 4.77), and SSIM (0.9592 ± 0.0252 / 0.9272 ± 0.0295), with statistically significant improvements from initial artifact images ( P < 0.001). Qualitatively, CLMAR received the highest physician rating on the RAD (3.87 ± 0.96 / 3.45 ± 0.91), indicating better artifact reduction compared to existing methods. CLMAR effectively reduces metal artifacts in post-surgical knee CT images, improving both training and inference efficiency. This enhancement increases image readability, enabling physicians to interpret post-surgical knee CT with greater accuracy. CLMAR significantly reduces metal artifacts in post-surgical knee CT scans, enhancing diagnostic accuracy and image readability. • CLMAR significantly reduces metal artifacts in post-surgical knee CT. • CLMAR outperforms other methods in quantitative and qualitative results. • CLMAR achieves superior metrics on simulated and real artifact datasets. • CLMAR shows fine generalization across different reconstruction methods. • CLMAR produces visually superior images with enhanced diagnostic quality.

Radiation Physics and ChemistryVol. 236
Beijing Institute of Technology (CN), First Affiliated Hospital of University of South China (CN), University of South China (CN)
University of South China, Key Research and Development Program of Hunan Province of China
Openalex Percentile: Top 89%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.