Immediate Implant-Based Breast Reconstruction Using TIGR® Matrix Surgical Mesh: Clinical Outcomes From Our First 100 Procedures

Background Implant-based reconstruction has advanced with the introduction of acellular dermal matrices (ADMs). However, ADMs are associated with higher complication rates. Synthetic meshes have emerged as cost-effective alternatives. This retrospective, single-center study evaluates the clinical outcomes of immediate implant-based breast reconstruction with TIGR® Mesh (Novus Scientific, Uppsala, Sweden) on 76 patients (100 breasts) performed between February 2020 and June 2022. Methods Eligible patients were ≥18 years old with no major comorbidities and underwent direct-to-implant (DTI) mastectomy. Complications were assessed using the Clavien-Dindo classification (grade III or higher). Cosmetic outcomes were refined with lipofilling when required. Results The mean patient age was 45.5 years, with a mean follow-up of 17.3 months. Twelve mesh-related grade III complications were observed (10 infections and two seromas) over a total of 21 events. Implant loss occurred in 10 cases, which were later reconstructed in a subsequent procedure. No variable was identified as a significant predictor of complications. A significant inverse correlation (p=0.03) was found between mastectomy weight and complication rate, with lower weights associated with higher risk. Additionally, 57 reconstructions required at least one lipofilling session, with heavier mastectomy specimens needing fewer sessions. Conclusions TIGR® Mesh demonstrated an acceptable safety profile, with infection and seroma rates falling within the lower range reported for synthetic meshes and lower than most ADM series. Its cost-effectiveness and favorable outcomes support its use in selected patients. Further prospective studies are warranted to confirm these findings.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-05-24
DOI
https://doi.org/10.7759/cureus.84745
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Immediate Implant-Based Breast Reconstruction Using TIGR® Matrix Surgical Mesh: Clinical Outcomes From Our First 100 Procedures

Mellie Heinemann, Marie Osdoit, Sylvie Chabaud, L. Rossi et al.
Cureus
Breast Implant and Reconstruction
article

Immediate Implant-Based Breast Reconstruction Using TIGR® Matrix Surgical Mesh: Clinical Outcomes From Our First 100 Procedures

Mellie Heinemann, Marie Osdoit, Sylvie Chabaud, L. Rossi, Sophie Klingler, Giorgio Caddia, Christelle Fauré, M A Dammacco
article en

Abstract

Background Implant-based reconstruction has advanced with the introduction of acellular dermal matrices (ADMs). However, ADMs are associated with higher complication rates. Synthetic meshes have emerged as cost-effective alternatives. This retrospective, single-center study evaluates the clinical outcomes of immediate implant-based breast reconstruction with TIGR® Mesh (Novus Scientific, Uppsala, Sweden) on 76 patients (100 breasts) performed between February 2020 and June 2022. Methods Eligible patients were ≥18 years old with no major comorbidities and underwent direct-to-implant (DTI) mastectomy. Complications were assessed using the Clavien-Dindo classification (grade III or higher). Cosmetic outcomes were refined with lipofilling when required. Results The mean patient age was 45.5 years, with a mean follow-up of 17.3 months. Twelve mesh-related grade III complications were observed (10 infections and two seromas) over a total of 21 events. Implant loss occurred in 10 cases, which were later reconstructed in a subsequent procedure. No variable was identified as a significant predictor of complications. A significant inverse correlation (p=0.03) was found between mastectomy weight and complication rate, with lower weights associated with higher risk. Additionally, 57 reconstructions required at least one lipofilling session, with heavier mastectomy specimens needing fewer sessions. Conclusions TIGR® Mesh demonstrated an acceptable safety profile, with infection and seroma rates falling within the lower range reported for synthetic meshes and lower than most ADM series. Its cost-effectiveness and favorable outcomes support its use in selected patients. Further prospective studies are warranted to confirm these findings.

CureusVol. 17(5)
Centre Léon Bérard (FR), Azienda Ospedaliera Universitaria Policlinico "G. Martino" (IT)
Gender equality
Openalex Percentile: Top 80%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.