Study on the improved method for natural gas analytical system performance evaluation

Abstract With the advancement of natural gas energy measurement methods by domestic governments, enterprises, and users, GB/T 28766-2018 Performance Evaluation of Natural Gas Analysis Systems has received increasing attention and widespread application since its release and implementation in 2018. However, most of the gas chromatography used domestically employs a single-point calibration function for sample analysis and cannot implant true regression functions, which significantly limits the application of the standard. Based on the standard method and the current state of the domestic natural gas industry, this paper proposes an improvement measure for the standard method and validates the improved method through actual measurements. The performance evaluation data from nine chromatography demonstrate that the proposed method can effectively identify equipment with issues.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3011/1/012030
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the improved method for natural gas analytical system performance evaluation

Lin Min, Ke Li, Chen Fuquan
Journal of Physics Conference Series
Scientific Measurement and Uncertainty Evaluation
article

Study on the improved method for natural gas analytical system performance evaluation

Lin Min, Ke Li, Chen Fuquan
article en

Abstract

Abstract With the advancement of natural gas energy measurement methods by domestic governments, enterprises, and users, GB/T 28766-2018 Performance Evaluation of Natural Gas Analysis Systems has received increasing attention and widespread application since its release and implementation in 2018. However, most of the gas chromatography used domestically employs a single-point calibration function for sample analysis and cannot implant true regression functions, which significantly limits the application of the standard. Based on the standard method and the current state of the domestic natural gas industry, this paper proposes an improvement measure for the standard method and validates the improved method through actual measurements. The performance evaluation data from nine chromatography demonstrate that the proposed method can effectively identify equipment with issues.

Journal of Physics Conference SeriesVol. 3011(1)
Chengdu University of Information Technology (CN), Line Corporation (Japan) (JP)
Openalex Percentile: Top 89%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.