Evaluation of Diagnostic Sensitivity and Specificity of a New Automatized Assay for Indirect Synthetic Urine Identification

Synthetic urine mimicking normal urine is difficult detectable by standard specimen validity testing. In this study, the VDx True Urine LD Test and True Urine SD Test, analysing 'long duration' (LD) and 'short duration' (SD) markers, were evaluated for their ability to detect synthetic urine. Two synthetic urines from the US market and 1188 real-life urine specimens were analysed for LD markers, SD markers, uric acid and temperature. Forty-seven specimens (set 1) showed uric acid and/or temperature suspicious results and were analysed by LC-MS/MS for 10 endogenous biomolecules. Diagnostic sensitivities and specificities were calculated for LD and SD markers based on uric acid and LC-MS/MS results of set 1. The false-positive rate of the SD marker was further evaluated with uric acid results of the other 1141 specimens (set 2). Additionally, direct synthetic urine markers were analysed by LC-(HR)MS. Uric acid and LC-MS/MS could identify synthetic urine. In one US synthetic urine, low concentrations of uric acid were found. Specimens of the Austrian/German region were reliably classified congruently by both methods. The LD and the SD markers detected both synthetic urines. For set 1, the LD had 100% sensitivity and 88.9% specificity, and the SD had 84.2% sensitivity and 44.4% specificity for authentic/synthetic specimens. In set 2, the SD marker specificity depended on the upper limit of the acceptance criteria. In one US synthetic urine, carbendazim was identified. Overall, several tests should be applied to confirm authentic or synthetic urine. Especially, simultaneous analysis of indirect and direct synthetic urine markers should be considered.

Authors

Institutions

Publication Details

Journal
Drug Testing and Analysis
Published
2025-05-22
DOI
https://doi.org/10.1002/dta.3908
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Diagnostic Sensitivity and Specificity of a New Automatized Assay for Indirect Synthetic Urine Identification

Dirk K. Wissenbach, Laura Franke, Christian Fuczik
Drug Testing and Analysis
Metabolomics and Mass Spectrometry Studies
article

Evaluation of Diagnostic Sensitivity and Specificity of a New Automatized Assay for Indirect Synthetic Urine Identification

Dirk K. Wissenbach, Laura Franke, Christian Fuczik
article en

Abstract

Synthetic urine mimicking normal urine is difficult detectable by standard specimen validity testing. In this study, the VDx True Urine LD Test and True Urine SD Test, analysing 'long duration' (LD) and 'short duration' (SD) markers, were evaluated for their ability to detect synthetic urine. Two synthetic urines from the US market and 1188 real-life urine specimens were analysed for LD markers, SD markers, uric acid and temperature. Forty-seven specimens (set 1) showed uric acid and/or temperature suspicious results and were analysed by LC-MS/MS for 10 endogenous biomolecules. Diagnostic sensitivities and specificities were calculated for LD and SD markers based on uric acid and LC-MS/MS results of set 1. The false-positive rate of the SD marker was further evaluated with uric acid results of the other 1141 specimens (set 2). Additionally, direct synthetic urine markers were analysed by LC-(HR)MS. Uric acid and LC-MS/MS could identify synthetic urine. In one US synthetic urine, low concentrations of uric acid were found. Specimens of the Austrian/German region were reliably classified congruently by both methods. The LD and the SD markers detected both synthetic urines. For set 1, the LD had 100% sensitivity and 88.9% specificity, and the SD had 84.2% sensitivity and 44.4% specificity for authentic/synthetic specimens. In set 2, the SD marker specificity depended on the upper limit of the acceptance criteria. In one US synthetic urine, carbendazim was identified. Overall, several tests should be applied to confirm authentic or synthetic urine. Especially, simultaneous analysis of indirect and direct synthetic urine markers should be considered.

Drug Testing and AnalysisVol. 17(10)
University of Applied Arts Vienna (AT), Biotest (Austria) (AT), Jena University Hospital (DE), Friedrich Schiller University Jena (DE)
Responsible consumption and production
Openalex Percentile: Top 90%
Metabolomics and Mass Spectrometry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.