Low-pressure tamponade due to hemothorax after transcatheter edge-to-edge repair of the mitral valve
The application of POCUS is crucial for detecting, diagnosing, and properly managing cardiac dysfunction and procedural complications associated with TEER. While tamponade is classically associated with a pericardial effusion and vena caval plethora, their absence does not dismiss the suspicion or diagnosis of tamponade. This case highlights the value of POCUS in assessing low-pressure tamponade caused by a large, pressurized pleural effusion. Clinical suspicion, supported by POCUS findings, was confirmed by a thoracentesis that resulted in immediate hemodynamic improvement.
Authors
- Tzonghuei Chen (ORCID: https://orcid.org/0000-0003-3508-1528)
- Shyamal Asher (ORCID: https://orcid.org/0000-0002-3344-0032)
- Paul Gordon (ORCID: https://orcid.org/0000-0002-6087-0898)
- Neel R. Sodha (ORCID: https://orcid.org/0000-0001-9720-9895)
- Nicholas Seidler (ORCID: https://orcid.org/0009-0007-0486-6847)
- Andrew Maslow
Institutions
- Brown University (US)
Publication Details
- Journal
- World Journal of Cardiology
- Published
- 2025-05-23
- DOI
- https://doi.org/10.4330/wjc.v17.i5.106567
- Primary Topic
- Ultrasound in Clinical Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00