Long-term mechanical synchrony in left bundle branch area pacing

Abstract Background Left bundle branch area pacing (LBBAP) has shown significant benefits, particularly through enhanced electromechanical synchrony in the left ventricle. However, its long-term mechanical effects are still not fully understood. Objective To assess the long-term mechanical synchrony in patients with LBBAP, using myocardial work (MW) and other echocardiographic parameters. Methods Patients with successful LBBAP for bradycardia pacing and preserved left ventricular ejection fraction (LVEF) were consecutively enrolled. Mechanical synchrony was assessed during follow-up using 2D echocardiographic variables, myocardial strain, and MW measurements. Two echocardiograms were performed with a minimum interval of 30 minutes: one during paced rhythm and, if feasible, another during spontaneous rhythm. LBBAP was assessed based on current criteria. Results The study included 149 patients: 114 with left bundle branch pacing (LBBP) and 35 with left ventricular septal pacing (LVSP), with a mean follow-up of 18.2 ± 7.2 months. V6 R-wave peak time, interpeak interval, and QRS duration showed significant reductions from implant (77.8±11.8 ms vs. 74.8±11.9 ms, p=0.001; 40.6±13.2 ms vs. 38.5±12.4 ms, p=0.044; and 115.7±12.9 ms vs. 109.3±13.2 ms, p<0.001, respectively) (Table 1). The mean pre-implant LVEF was 61.6±4.9%, while follow-up non-paced LVEF was 57.3±5.7% (p<0.001). There was no significant difference between paced LVEF (57.5±4.3%) and non-paced LVEF (57.2±5.6%) at follow-up (p=0.481). Left ventricular end-diastolic and end-systolic volumes were slightly lower during pacing than during non-pacing (70.7±20.7 vs. 74.3±20.5, p=0.003, and 32.5±10.4 vs. 34.3±11.1, p=0.031, respectively). Interventricular mechanical delay (IVMD) did not differ significantly between intrinsic and paced beats (32.4±16.1 vs. 29.4±16.2, p=0.101). Peak strain dispersion (PSD) was slightly reduced during paced beats (62.1±21.2 vs. 69.8±27.5, p=0.013). Global longitudinal strain (GLS) did not differ significantly between intrinsic and paced beats (-14.4±6.8 vs. -14.9±7.0, p=0.071). The global work index (GWI) was similar between groups (1513.3±399.6 vs. 1496.7±400.2, p=0.723). However, paced beats showed higher global constructive work (GCW) (2148.0±434.2 vs. 1993.9±388.2, p<0.001) and global wasted work (GWW) (264.8±136.8 vs. 222.0±138.2, p=0.004), with no significant difference in global work efficiency (GWE) (88.2±4.5 vs. 88.9±5.2, p=0.189). These trends were consistent across patients with both narrow and wide baseline QRS (Table 2). Conclusions Consistent with improvements in electrical synchrony, mechanical synchrony parameters showed positive long-term outcomes. LBBAP-mediated beats demonstrated performance comparable to intrinsic beats in terms of ventricular volumes, LVEF, and advanced parameters of myocardial work and efficiency.Table 1.Electrical synchrony parameters Table 2.Mechanical synchrony parameters

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.537
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-term mechanical synchrony in left bundle branch area pacing

A Estevez Paniagua, Silvia Jiménez Loeches, S Briongos Figuero, Delia Heredero Palomo et al.
EP Europace
Neurological disorders and treatments
article

Long-term mechanical synchrony in left bundle branch area pacing

A Estevez Paniagua, Silvia Jiménez Loeches, S Briongos Figuero, Delia Heredero Palomo, E Sanchez Lopez, M Tapia Martinez, R Munoz Aguilera, A Luna Cabadas, A Sanchez Hernandez
article en

Abstract

Abstract Background Left bundle branch area pacing (LBBAP) has shown significant benefits, particularly through enhanced electromechanical synchrony in the left ventricle. However, its long-term mechanical effects are still not fully understood. Objective To assess the long-term mechanical synchrony in patients with LBBAP, using myocardial work (MW) and other echocardiographic parameters. Methods Patients with successful LBBAP for bradycardia pacing and preserved left ventricular ejection fraction (LVEF) were consecutively enrolled. Mechanical synchrony was assessed during follow-up using 2D echocardiographic variables, myocardial strain, and MW measurements. Two echocardiograms were performed with a minimum interval of 30 minutes: one during paced rhythm and, if feasible, another during spontaneous rhythm. LBBAP was assessed based on current criteria. Results The study included 149 patients: 114 with left bundle branch pacing (LBBP) and 35 with left ventricular septal pacing (LVSP), with a mean follow-up of 18.2 ± 7.2 months. V6 R-wave peak time, interpeak interval, and QRS duration showed significant reductions from implant (77.8±11.8 ms vs. 74.8±11.9 ms, p=0.001; 40.6±13.2 ms vs. 38.5±12.4 ms, p=0.044; and 115.7±12.9 ms vs. 109.3±13.2 ms, p<0.001, respectively) (Table 1). The mean pre-implant LVEF was 61.6±4.9%, while follow-up non-paced LVEF was 57.3±5.7% (p<0.001). There was no significant difference between paced LVEF (57.5±4.3%) and non-paced LVEF (57.2±5.6%) at follow-up (p=0.481). Left ventricular end-diastolic and end-systolic volumes were slightly lower during pacing than during non-pacing (70.7±20.7 vs. 74.3±20.5, p=0.003, and 32.5±10.4 vs. 34.3±11.1, p=0.031, respectively). Interventricular mechanical delay (IVMD) did not differ significantly between intrinsic and paced beats (32.4±16.1 vs. 29.4±16.2, p=0.101). Peak strain dispersion (PSD) was slightly reduced during paced beats (62.1±21.2 vs. 69.8±27.5, p=0.013). Global longitudinal strain (GLS) did not differ significantly between intrinsic and paced beats (-14.4±6.8 vs. -14.9±7.0, p=0.071). The global work index (GWI) was similar between groups (1513.3±399.6 vs. 1496.7±400.2, p=0.723). However, paced beats showed higher global constructive work (GCW) (2148.0±434.2 vs. 1993.9±388.2, p<0.001) and global wasted work (GWW) (264.8±136.8 vs. 222.0±138.2, p=0.004), with no significant difference in global work efficiency (GWE) (88.2±4.5 vs. 88.9±5.2, p=0.189). These trends were consistent across patients with both narrow and wide baseline QRS (Table 2). Conclusions Consistent with improvements in electrical synchrony, mechanical synchrony parameters showed positive long-term outcomes. LBBAP-mediated beats demonstrated performance comparable to intrinsic beats in terms of ventricular volumes, LVEF, and advanced parameters of myocardial work and efficiency.Table 1.Electrical synchrony parameters Table 2.Mechanical synchrony parameters

EP EuropaceVol. 27(Supplement_1)
Hospital Central de la Defensa Gómez Ulla (ES), Hospital Universitario Infanta Leonor (ES)
Openalex Percentile: Top 81%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.