A proposal for a novel formula for measurement of corrected QT interval in patients undergoing left bundle branch area pacing

Abstract Background The QT prolongation is associated with malignant ventricular arrhythmias. However, it is difficult to evaluate QT interval in specific conditions, like in ventricular paced rhythm. The data is scarce about optimal methodology of QT interval measurement in these patients. Herein, we proposed a novel formula for measurement of QT interval in patients with pacemaker implantation via left bundle branch area pacing (LBBaP). Methods This is a single-center, retrospective preliminary study (n=63). All patients underwent pacemaker implantation via LBBaP. Electrocardiographic (ECG) parameters [QRS duration (QRSd), QTc (Bazett, Fridericia, Framingham, Hodges, Rautuharju, Spline), Ventricular rate, JT interval] were measured and analyzed before and after the procedure. Results The mean age of the study population was 68±13 years, and n=39 (62%) of the patients were female. The mean left ventricular ejection fraction (LVEF) of the patients was 57.9%±4.78. The mean QT interval of the patients was 437.73 ± 55 msec at baseline and 427.17 ± 38.79 msec after the procedure. It was observed that the QTc interval was prolonged in all formulations after the LBBaP procedure. In the analysis of corrected QT (QTc) intervals before and after the procedure, the Hodges formula revealed a closer measurement to the baseline QTc interval. As a result of our analysis, we proposed a novel formula for patients undergoing LBBaP and in paced rhythm: QTc(Dogan)=QTc(H)X0.97=[QT + 1.75 (HR − 60)]x0.97. Conclusion There is no clear formula yet for measuring QTc interval in patients with ventricular paced rhythm. In patients with conventional pacemaker implantation, the QT interval has long been calculated by subtracting 50 msec from the QT interval in ventricular paced rhythm. However, the LBBaP is a physiological method compared to conventional pacemaker implantation and its application will increase in future. Thus, a novel formula for proper QT interval measurement is required in those patients with LBBaP.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.026
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A proposal for a novel formula for measurement of corrected QT interval in patients undergoing left bundle branch area pacing

Kudret Aytemir, Uğur Canpolat, Meral Dogan
EP Europace
Cardiac pacing and defibrillation studies
article

A proposal for a novel formula for measurement of corrected QT interval in patients undergoing left bundle branch area pacing

Kudret Aytemir, Uğur Canpolat, Meral Dogan
article en

Abstract

Abstract Background The QT prolongation is associated with malignant ventricular arrhythmias. However, it is difficult to evaluate QT interval in specific conditions, like in ventricular paced rhythm. The data is scarce about optimal methodology of QT interval measurement in these patients. Herein, we proposed a novel formula for measurement of QT interval in patients with pacemaker implantation via left bundle branch area pacing (LBBaP). Methods This is a single-center, retrospective preliminary study (n=63). All patients underwent pacemaker implantation via LBBaP. Electrocardiographic (ECG) parameters [QRS duration (QRSd), QTc (Bazett, Fridericia, Framingham, Hodges, Rautuharju, Spline), Ventricular rate, JT interval] were measured and analyzed before and after the procedure. Results The mean age of the study population was 68±13 years, and n=39 (62%) of the patients were female. The mean left ventricular ejection fraction (LVEF) of the patients was 57.9%±4.78. The mean QT interval of the patients was 437.73 ± 55 msec at baseline and 427.17 ± 38.79 msec after the procedure. It was observed that the QTc interval was prolonged in all formulations after the LBBaP procedure. In the analysis of corrected QT (QTc) intervals before and after the procedure, the Hodges formula revealed a closer measurement to the baseline QTc interval. As a result of our analysis, we proposed a novel formula for patients undergoing LBBaP and in paced rhythm: QTc(Dogan)=QTc(H)X0.97=[QT + 1.75 (HR − 60)]x0.97. Conclusion There is no clear formula yet for measuring QTc interval in patients with ventricular paced rhythm. In patients with conventional pacemaker implantation, the QT interval has long been calculated by subtracting 50 msec from the QT interval in ventricular paced rhythm. However, the LBBaP is a physiological method compared to conventional pacemaker implantation and its application will increase in future. Thus, a novel formula for proper QT interval measurement is required in those patients with LBBaP.

EP EuropaceVol. 27(Supplement_1)
Hacettepe University (TR)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.