Acute and long-term results of atrial fibrillation cryoablation guided by pressure waveforms: a multicentre registry

Abstract Background Cryoballoon ablation (CA) procedures require optimal occlusion of the pulmonary veins (PV), which is conventionally evaluated by contrast injection through the catheter tip. This technique has some weaknesses such as risk of allergic reactions, nephrotoxicity, requirement of a second operator, among others. PV pressure waveform analysis is an alternative method for confirming occlusion, however, multicentre assessment of periprocedural efficacy and safety is lacking. Purpose To describe the intra-procedural performance, safety and long-term results of routine pressure-based CA. Methods In this independent prospective multicentre and multi-brand observational study, baseline, procedural and follow-up data from consecutive pressure-guided cryoballoon ablations were collected. Pressure waveforms were classified into type 1 (presence of "a-wave" and/or symmetric "v-wave", meaning incomplete PV occlusion) and type 2 (absence of "a-wave" and asymmetric "v-wave", meaning complete PV occlusion). Results A total of 235 patients (mean age: 61 ± 10 y.) with paroxysmal (57.8%) or persistent AF (42.2%) from 9 centres were enrolled. Complete PV isolation was achieved in 226 patients (97%). The operators switched to contrast in 16 cases (6.8%). Thirteen non-serious (5.5%) and 0 serious procedure-related adverse events were reported. AF/AT-free survival rate after the index procedure was 60.3% after a median follow-up of 359 days. Ten patients (4.3%) required a second procedure. Conclusion Routine PV cryoablation guided exclusively by pressure waveforms was safe and could be achieved in most of the patients. No contrast requirement and a high single shot isolation rate (78%) were important advantages of this approach. Long-term clinical efficacy was equivalent to that reported with the conventional approach.Pressure waveforms classification Catheters,procedural & clinical outcomes

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.185
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acute and long-term results of atrial fibrillation cryoablation guided by pressure waveforms: a multicentre registry

J A Cabrera Rodriguez, A Izquierdo Bajo, Adolfo Fontenla, J M Medina Suarez et al.
EP Europace
Atrial Fibrillation Management and Outcomes
article

Acute and long-term results of atrial fibrillation cryoablation guided by pressure waveforms: a multicentre registry

J A Cabrera Rodriguez, A Izquierdo Bajo, Adolfo Fontenla, J M Medina Suarez, J. Serra López, Larraitz Gaztañaga Arantzamendi, Pablo Sánchez‐Millán, Rocío Cózar León, Gabriel Ballesteros, Jorge G. Panizo, David Casal, Tomás Datino, Miguel Álvarez López, Gerardo Palacios, NA Flores
article en

Abstract

Abstract Background Cryoballoon ablation (CA) procedures require optimal occlusion of the pulmonary veins (PV), which is conventionally evaluated by contrast injection through the catheter tip. This technique has some weaknesses such as risk of allergic reactions, nephrotoxicity, requirement of a second operator, among others. PV pressure waveform analysis is an alternative method for confirming occlusion, however, multicentre assessment of periprocedural efficacy and safety is lacking. Purpose To describe the intra-procedural performance, safety and long-term results of routine pressure-based CA. Methods In this independent prospective multicentre and multi-brand observational study, baseline, procedural and follow-up data from consecutive pressure-guided cryoballoon ablations were collected. Pressure waveforms were classified into type 1 (presence of "a-wave" and/or symmetric "v-wave", meaning incomplete PV occlusion) and type 2 (absence of "a-wave" and asymmetric "v-wave", meaning complete PV occlusion). Results A total of 235 patients (mean age: 61 ± 10 y.) with paroxysmal (57.8%) or persistent AF (42.2%) from 9 centres were enrolled. Complete PV isolation was achieved in 226 patients (97%). The operators switched to contrast in 16 cases (6.8%). Thirteen non-serious (5.5%) and 0 serious procedure-related adverse events were reported. AF/AT-free survival rate after the index procedure was 60.3% after a median follow-up of 359 days. Ten patients (4.3%) required a second procedure. Conclusion Routine PV cryoablation guided exclusively by pressure waveforms was safe and could be achieved in most of the patients. No contrast requirement and a high single shot isolation rate (78%) were important advantages of this approach. Long-term clinical efficacy was equivalent to that reported with the conventional approach.Pressure waveforms classification Catheters,procedural & clinical outcomes

EP EuropaceVol. 27(Supplement_1)
Hospital Universitario Virgen Macarena (ES), Hospital de Basurto (ES), Hospital Universitario de Gran Canaria Doctor Negrín (ES), Hospital Regional Universitario de Málaga (ES), Hospital Universitario Quirónsalud Madrid (ES), Hospital Universitario Virgen de las Nieves (ES), Hospital Del Mar (ES), Hospital Ruber Internacional (ES)
Sociedad Española de Cardiología
Openalex Percentile: Top 79%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.