Conduction system versus biventricular pacing upgrade in patients with pacing-induced cardiomyopathy

Abstract Background The feasibility and outcome of conduction system pacing (CSP) upgrade as an alternative modality to the traditional biventricular pacing (BVP) upgrade in patients with pacing-induced cardiomyopathy (PICM) remain uncertain. Purpose We conducted an observational study aimed to compare CSP upgrade (His bundle pacing, HBP, or left bundle branch area pacing, LBBAP) with BVP upgrade in patients with PICM. Methods Consecutive patients with PICM who underwent CSP or BVP upgrade from 2018 to 2023 were included in the analysis. Echocardiographic response and the risk of a composite end-point including all-cause death or heart failure (HF) hospitalization were assessed during follow-up. Results Eighty-six consecutive patients (79.7±7.0 years, 64.9% male, mean left ventricular ejection fraction, LVEF, 33.1±8.1%, mean NYHA class 3.0±0.4, mean duration of paced QRS 189.8±21.1 ms) were enrolled in the study: 37 underwent CSP upgrade (8 HBP, 29 LBBAP), and 49 underwent BVP upgrade. Compared to BVP upgrade, CSP upgrade was associated with a significantly narrower paced QRS (126.6±15.2 vs 147.8±17.0 ms; p<0.001). After a median follow-up of 22 months, patients who had undergone CSP upgrade showed a similar increase in LVEF (+13.5 vs +12.6%; p=0.824), a similar risk of procedure-related complications (0 vs 4.1%; p=0.214), and a similar risk of the composite end-point of all-cause death or HF hospitalization (13.5 vs 18.4%; p=0.546, Figure) compared to patients who had undergone BVP upgrade. Conclusion CSP upgrade appears to be a valid alternative to BVP upgrade for the treatment of patients with PICM, with similar echocardiographic and clinical outcomes.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.607
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conduction system versus biventricular pacing upgrade in patients with pacing-induced cardiomyopathy

Michele Accogli, A. Guido, Silvia Bonanno, G. De Luca et al.
EP Europace
Cardiac pacing and defibrillation studies
article

Conduction system versus biventricular pacing upgrade in patients with pacing-induced cardiomyopathy

Michele Accogli, A. Guido, Silvia Bonanno, G. De Luca, P Palmisano, Giovanni Coluccia, Antonio Parlavecchio, Giovanni Carreras, M Giuranna, Maurizio Collantoni
article en

Abstract

Abstract Background The feasibility and outcome of conduction system pacing (CSP) upgrade as an alternative modality to the traditional biventricular pacing (BVP) upgrade in patients with pacing-induced cardiomyopathy (PICM) remain uncertain. Purpose We conducted an observational study aimed to compare CSP upgrade (His bundle pacing, HBP, or left bundle branch area pacing, LBBAP) with BVP upgrade in patients with PICM. Methods Consecutive patients with PICM who underwent CSP or BVP upgrade from 2018 to 2023 were included in the analysis. Echocardiographic response and the risk of a composite end-point including all-cause death or heart failure (HF) hospitalization were assessed during follow-up. Results Eighty-six consecutive patients (79.7±7.0 years, 64.9% male, mean left ventricular ejection fraction, LVEF, 33.1±8.1%, mean NYHA class 3.0±0.4, mean duration of paced QRS 189.8±21.1 ms) were enrolled in the study: 37 underwent CSP upgrade (8 HBP, 29 LBBAP), and 49 underwent BVP upgrade. Compared to BVP upgrade, CSP upgrade was associated with a significantly narrower paced QRS (126.6±15.2 vs 147.8±17.0 ms; p<0.001). After a median follow-up of 22 months, patients who had undergone CSP upgrade showed a similar increase in LVEF (+13.5 vs +12.6%; p=0.824), a similar risk of procedure-related complications (0 vs 4.1%; p=0.214), and a similar risk of the composite end-point of all-cause death or HF hospitalization (13.5 vs 18.4%; p=0.546, Figure) compared to patients who had undergone BVP upgrade. Conclusion CSP upgrade appears to be a valid alternative to BVP upgrade for the treatment of patients with PICM, with similar echocardiographic and clinical outcomes.

EP EuropaceVol. 27(Supplement_1)
University of Siena (IT), Santa Maria Nuova Hospital (IT), Martin University (US)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.