Impact of integrated 3D imaging and fluoroscopy fusion during pulsed field ablation

Abstract Background Three-dimensional rotational angiography (3DRA) allows real-time 3D reconstruction of the left atrium (LA) and integration in the fluoroscopy image. As such it provides anatomical guidance which can be valuable during single shot ablation procedures. There are no data estimating efficiency and effectiveness in the context of pulsed field ablation (PFA) of atrial fibrillation (AF). Purpose We sought to investigate the impact of 3DRA on the procedural parameters in consecutive patients who underwent AF ablation with PFA technology. Methods All consecutive patients who underwent AF ablation with PFA at two experienced centers from November 2023 until October 2024 were eligible for this study. Operators performed pulmonary vein isolation (PVI) using device-specific instructions resulting in eight applications (four basket and 4 flower poses) for each vein. Additional lesions were done at the operator discretion. Procedural metrics were analysed according to the use of 3DRA which was used according to institutional standards. Results Four hundred and four patients were included in this study. 62.9% of the population had paroxysmal AF, and 37.1% had persistent AF. 3DRA was used in 239 cases (59.2%) (Figure 1). Patients with peri-procedural 3DRA received fewer additional applications compared to patients without (applications per patients 38 [32-45] vs 40 [34-53], p =0.012). Median fluoroscopy time was 15 [10-22] min, median LA dwell time was 30 [25-37] min, and median skin-to-skin time was 41 [35-51] min. The use of 3DRA improved the procedural metrics (3DRA vs no 3DRA: 39 [34-48] min vs 45 [38-53] min for skin-to-skin time, p <0.001; 11 [9-16] min vs 20 [15-24] min for total fluoroscopy time p <0.001, and 9 [7-13] vs 20 [15-24] for fluoroscopy time during PFA) (Figure 2). Conclusion In our study, the integration of 3DRA during PVI with PFA may provide advantages in terms of procedural metrics, such as the decrease in both the total procedural time and the total fluoroscopy dose. These improvements may be a result of the anatomical information provided by the 3D model.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.408
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of integrated 3D imaging and fluoroscopy fusion during pulsed field ablation

Dimitri Buytaert, P. Geelen, K P Gkini, Tom J. R. De Potter et al.
EP Europace
Laser-induced spectroscopy and plasma
article

Impact of integrated 3D imaging and fluoroscopy fusion during pulsed field ablation

Dimitri Buytaert, P. Geelen, K P Gkini, Tom J. R. De Potter, Philippe Vanduynhoven, K De Schouwer, P. Peytchev, Guy Meyer
article en

Abstract

Abstract Background Three-dimensional rotational angiography (3DRA) allows real-time 3D reconstruction of the left atrium (LA) and integration in the fluoroscopy image. As such it provides anatomical guidance which can be valuable during single shot ablation procedures. There are no data estimating efficiency and effectiveness in the context of pulsed field ablation (PFA) of atrial fibrillation (AF). Purpose We sought to investigate the impact of 3DRA on the procedural parameters in consecutive patients who underwent AF ablation with PFA technology. Methods All consecutive patients who underwent AF ablation with PFA at two experienced centers from November 2023 until October 2024 were eligible for this study. Operators performed pulmonary vein isolation (PVI) using device-specific instructions resulting in eight applications (four basket and 4 flower poses) for each vein. Additional lesions were done at the operator discretion. Procedural metrics were analysed according to the use of 3DRA which was used according to institutional standards. Results Four hundred and four patients were included in this study. 62.9% of the population had paroxysmal AF, and 37.1% had persistent AF. 3DRA was used in 239 cases (59.2%) (Figure 1). Patients with peri-procedural 3DRA received fewer additional applications compared to patients without (applications per patients 38 [32-45] vs 40 [34-53], p =0.012). Median fluoroscopy time was 15 [10-22] min, median LA dwell time was 30 [25-37] min, and median skin-to-skin time was 41 [35-51] min. The use of 3DRA improved the procedural metrics (3DRA vs no 3DRA: 39 [34-48] min vs 45 [38-53] min for skin-to-skin time, p <0.001; 11 [9-16] min vs 20 [15-24] min for total fluoroscopy time p <0.001, and 9 [7-13] vs 20 [15-24] for fluoroscopy time during PFA) (Figure 2). Conclusion In our study, the integration of 3DRA during PVI with PFA may provide advantages in terms of procedural metrics, such as the decrease in both the total procedural time and the total fluoroscopy dose. These improvements may be a result of the anatomical information provided by the 3D model.

EP EuropaceVol. 27(Supplement_1)
Onze Lieve Vrouwziekenhuis Hospital (BE)
Openalex Percentile: Top 87%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.