Conventional pulsed-field ablation versus pulsed-field ablation with non-navigated three-dimensional mapping on the safety and efficacy for de novo pulmonary vein isolation during atrial fibrillation

Abstract Background Visualization of the multi-electrode pulsed-field ablation (PFA) catheter within a three-dimensional (3D) mapping system holds the potential to improve catheter maneuverability and enhance ablation outcomes, thereby improving procedural metrics and long-term outcome. Purpose The aim of our analysis, from a real-world nationwide registry, is to evaluate the impact of PFA with non-navigated 3D-mapping systems on safety and efficacy in the context of de novo pulmonary vein isolation (PVI) during atrial fibrillation (AF) ablation. Methods All consecutive patients undergoing de novo PVI-only AF ablation with the Farapulse system at 18 centers were included. A standard protocol-directed PVI was delivered using 2kV with 8 applications per vein. Additional lesions at PVs were performed at the operator’s discretion. Procedures were stratified according to the use or not of a non-integrated 3D-mapping system to validate the lesions (MAP vs Standard). Primary efficacy endpoint was freedom from any atrial arrhythmia recurrence during the follow-up period. Results Among 1184 patients, 321 (27.1%) were females, 1010 (85.3%) had paroxysmal AF (174 -14.7%- persistent AF), mean age was 62.0±10 years, mean LVEF was 58.4±7%. A 3D-mapping system was used to validate the lesion set in 223 (18.8%) of the cases. The number of patients with all PV isolated at first pass was 1129 (95.4%) with no difference between MAP and Standard procedures (STD: 95.7% vs MAP: 93.7%, p=0.215). The total number of PFA deliveries (38±8 vs 37±8, p=0.147) was similar between groups, while MAP procedures had longer skin-to-skin time (90[70-110] min vs 55[47-70] min, p<0.0001), Cath lab utilization time (120[105-150] min vs 70[60-90] min, p<0.0001), time to PVI (21[15-27] min vs 19[15-24] min, p=0.0002) or fluoroscopy time (21[16-27] min vs 15[11-21] min, p<0.0001). During a mean follow-up of 328[191-385] days, primary efficacy endpoint occurred in 689 out 809 (85.2%) patients with available outcome information. STD and MAP patients exhibited a similar arrhythmia recurrence rate (15.6% for STD cases, 10.9% for MAP cases, p=0.222). At cox regression analysis, no difference was found between STD and MAP patients (HR=0.8, 95%CI: 0.46 to 1.39, p=0.429), the time to recurrence was similar between groups (log-rank p=0.427). Two (0.2%) major complications occurred, all in the STD group. Conclusion In our real-life experience, the use of Farapulse PFA system for de novo PVI-only AF ablation was rapid, safe and effective leading to a high first-pass isolation rate and freedom from atrial arrhythmias during follow-up. A non-integrated 3D-mapping system was employed in a minority of cases and did not significantly affect acute or long-term success rates.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.123
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conventional pulsed-field ablation versus pulsed-field ablation with non-navigated three-dimensional mapping on the safety and efficacy for de novo pulmonary vein isolation during atrial fibrillation

Pietro Rossi, V Schillaci, Maurizio Russo, M Malacrida et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Conventional pulsed-field ablation versus pulsed-field ablation with non-navigated three-dimensional mapping on the safety and efficacy for de novo pulmonary vein isolation during atrial fibrillation

Pietro Rossi, V Schillaci, Maurizio Russo, M Malacrida, C Tondo, Roberto Rordorf, Gianluca Zingarini, Antonio Sanzo, Saverio Iacopino, Andrea Di Cori, Dario Argiolas, Antonio Dello Russo, F Solimene, R Maggio, B Stegagno
article en

Abstract

Abstract Background Visualization of the multi-electrode pulsed-field ablation (PFA) catheter within a three-dimensional (3D) mapping system holds the potential to improve catheter maneuverability and enhance ablation outcomes, thereby improving procedural metrics and long-term outcome. Purpose The aim of our analysis, from a real-world nationwide registry, is to evaluate the impact of PFA with non-navigated 3D-mapping systems on safety and efficacy in the context of de novo pulmonary vein isolation (PVI) during atrial fibrillation (AF) ablation. Methods All consecutive patients undergoing de novo PVI-only AF ablation with the Farapulse system at 18 centers were included. A standard protocol-directed PVI was delivered using 2kV with 8 applications per vein. Additional lesions at PVs were performed at the operator’s discretion. Procedures were stratified according to the use or not of a non-integrated 3D-mapping system to validate the lesions (MAP vs Standard). Primary efficacy endpoint was freedom from any atrial arrhythmia recurrence during the follow-up period. Results Among 1184 patients, 321 (27.1%) were females, 1010 (85.3%) had paroxysmal AF (174 -14.7%- persistent AF), mean age was 62.0±10 years, mean LVEF was 58.4±7%. A 3D-mapping system was used to validate the lesion set in 223 (18.8%) of the cases. The number of patients with all PV isolated at first pass was 1129 (95.4%) with no difference between MAP and Standard procedures (STD: 95.7% vs MAP: 93.7%, p=0.215). The total number of PFA deliveries (38±8 vs 37±8, p=0.147) was similar between groups, while MAP procedures had longer skin-to-skin time (90[70-110] min vs 55[47-70] min, p<0.0001), Cath lab utilization time (120[105-150] min vs 70[60-90] min, p<0.0001), time to PVI (21[15-27] min vs 19[15-24] min, p=0.0002) or fluoroscopy time (21[16-27] min vs 15[11-21] min, p<0.0001). During a mean follow-up of 328[191-385] days, primary efficacy endpoint occurred in 689 out 809 (85.2%) patients with available outcome information. STD and MAP patients exhibited a similar arrhythmia recurrence rate (15.6% for STD cases, 10.9% for MAP cases, p=0.222). At cox regression analysis, no difference was found between STD and MAP patients (HR=0.8, 95%CI: 0.46 to 1.39, p=0.429), the time to recurrence was similar between groups (log-rank p=0.427). Two (0.2%) major complications occurred, all in the STD group. Conclusion In our real-life experience, the use of Farapulse PFA system for de novo PVI-only AF ablation was rapid, safe and effective leading to a high first-pass isolation rate and freedom from atrial arrhythmias during follow-up. A non-integrated 3D-mapping system was employed in a minority of cases and did not significantly affect acute or long-term success rates.

EP EuropaceVol. 27(Supplement_1)
Boston Scientific (United States) (US), Centro Cardiologico Monzino (IT), Ospedale San Filippo Neri (IT), Maria Cecilia Hospital (IT), Fatebenefratelli Hospital (IT), Ospedale SS. Annunziata (IT), Policlinico San Matteo Fondazione (IT), Ospedale degli Infermi (IT), Hospital Montecelo (ES), Ospedali Riuniti Umberto I (IT), Azienda Ospedaliera Universitaria Pisana (IT), Misericordia University (US)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.