Deep learning and iterative image reconstruction for head CT: Impact on image quality and radiation dose reduction—Comparative study

<b>Background and purpose:</b> This study focuses on an objective evaluation of a novel reconstruction algorithm-Deep Learning Image Reconstruction (DLIR)-ability to improve image quality and reduce radiation dose compared to the established standard of Adaptive Statistical Iterative Reconstruction-V (ASIR-V), in unenhanced head computed tomography (CT). <b>Materials and methods:</b> A retrospective analysis of 163 consecutive unenhanced head CTs was conducted. Image quality assessment was computed on the objective parameters of Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR), derived from 5 regions of interest (ROI). The evaluation of DLIR dose reduction abilities was based on the analysis of the PACS derived parameters of dose length product and computed tomography dose index volume (CTDIvol). <b>Results:</b> Following the application of rigorous criteria, the study comprised 35 patients. Significant image quality improvement was achieved with the implementation of DLIR, as evidenced by up to a 145% and 160% increase in SNR in supra- and infratentorial regions, respectively. CNR measurements further confirmed the superiority of DLIR over ASIR-V, with an increase of 171.5% in the supratentorial region and a 59.3% increase in the infratentorial region. Despite the signal improvement and noise reduction DLIR facilitated radiation dose reduction of up to 44% in CTDIvol. <b>Conclusion:</b> Implementation of DLIR in head CT scans enables significant image quality improvement and dose reduction abilities compared to standard ASIR-V. However, the dose reduction feature was proven insufficient to counteract the lack of gantry angulation in wide-detector scanners.

Authors

Institutions

Publication Details

Journal
The Neuroradiology Journal
Published
2025-05-23
DOI
https://doi.org/10.1177/19714009251345108
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning and iterative image reconstruction for head CT: Impact on image quality and radiation dose reduction—Comparative study

Maciej Guziński, Emilia Kucharczyk, Mateusz Dorochowicz, Michał Puła et al.
1 citations
The Neuroradiology Journal
Radiation Dose and Imaging
1.36
article

Deep learning and iterative image reconstruction for head CT: Impact on image quality and radiation dose reduction—Comparative study

Maciej Guziński, Emilia Kucharczyk, Mateusz Dorochowicz, Michał Puła, Agata Zdanowicz-Ratajczyk
article en
1 citations

Abstract

<b>Background and purpose:</b> This study focuses on an objective evaluation of a novel reconstruction algorithm-Deep Learning Image Reconstruction (DLIR)-ability to improve image quality and reduce radiation dose compared to the established standard of Adaptive Statistical Iterative Reconstruction-V (ASIR-V), in unenhanced head computed tomography (CT). <b>Materials and methods:</b> A retrospective analysis of 163 consecutive unenhanced head CTs was conducted. Image quality assessment was computed on the objective parameters of Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR), derived from 5 regions of interest (ROI). The evaluation of DLIR dose reduction abilities was based on the analysis of the PACS derived parameters of dose length product and computed tomography dose index volume (CTDIvol). <b>Results:</b> Following the application of rigorous criteria, the study comprised 35 patients. Significant image quality improvement was achieved with the implementation of DLIR, as evidenced by up to a 145% and 160% increase in SNR in supra- and infratentorial regions, respectively. CNR measurements further confirmed the superiority of DLIR over ASIR-V, with an increase of 171.5% in the supratentorial region and a 59.3% increase in the infratentorial region. Despite the signal improvement and noise reduction DLIR facilitated radiation dose reduction of up to 44% in CTDIvol. <b>Conclusion:</b> Implementation of DLIR in head CT scans enables significant image quality improvement and dose reduction abilities compared to standard ASIR-V. However, the dose reduction feature was proven insufficient to counteract the lack of gantry angulation in wide-detector scanners.

The Neuroradiology JournalVol. 39(1)
Wrocław University of Science and Technology (PL), University of Wrocław (PL), Wroclaw Medical University (PL)
Uniwersytet Medyczny im. Piastów Slaskich we Wroclawiu
Openalex Percentile: Top 20%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.