Use of 2D‐Shear Wave Elastography for the Evaluation of Lens in Horses

Although lens diseases are uncommon in horses, they can be disabling in advanced stages. The B-mode ultrasound is useful for diagnosing and monitoring the progression of ocular diseases such as cataracts. Elastography is an ultrasonographic technique that allows the detection and measurement of tissue stiffness. This observational cohort prospective study aimed to determine the feasibility, reproducibility, and repeatability of 2D-shear wave elastography (2D-SWE) of lenses in horses. Forty-six eyes of 23 horses with no evidence of ocular disease were included in this study. The horses underwent an ophthalmic examination to ensure that they were healthy. After the B-mode ultrasound examination, 2D-SWE was performed by two operators with different levels of experience in diagnostic imaging. Elastographic images were independently analyzed quantitatively by two observers by measuring the shear wave velocity (m/s) and Young's modulus (kPa). Considering both right and left eyes, the mean shear wave velocity was 4.08 ± 0.71 m/s, and the mean Young's modulus was 51.30 ± 19.02 kPa. Interoperator and intraoperator agreements were excellent. The intra-observer agreement was good, with only one value for each observer that presented statistically significant differences. No statistically significant differences were observed between the right and left eyes. The excellent reliability, reproducibility, and good repeatability between evaluators make 2D-SWE a practical and reproducible technique that can be applied in clinical settings, where different sonographers often obtain images on multiple separate occasions. Our findings support the future clinical application of 2D-SW elastography as a noninvasive imaging modality for normal lens evaluation in horses.

Authors

Institutions

Publication Details

Journal
Veterinary Radiology & Ultrasound
Published
2025-05-01
DOI
https://doi.org/10.1111/vru.70052
Citations
1
Primary Topic
Veterinary Equine Medical Research
Type
article
Field-Weighted Citation Impact
2.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of 2D‐Shear Wave Elastography for the Evaluation of Lens in Horses

Lucio Petrizzi, Massimo Vignoli, Gianluca Celani, Giulia Guerri et al.
1 citations
Veterinary Radiology & Ultrasound
Veterinary Equine Medical Research
2.73
article

Use of 2D‐Shear Wave Elastography for the Evaluation of Lens in Horses

Lucio Petrizzi, Massimo Vignoli, Gianluca Celani, Giulia Guerri, Vincenzo Varasano, L Bandera, Paola Straticò, Maria Cristina Pincelli
article en
1 citations

Abstract

Although lens diseases are uncommon in horses, they can be disabling in advanced stages. The B-mode ultrasound is useful for diagnosing and monitoring the progression of ocular diseases such as cataracts. Elastography is an ultrasonographic technique that allows the detection and measurement of tissue stiffness. This observational cohort prospective study aimed to determine the feasibility, reproducibility, and repeatability of 2D-shear wave elastography (2D-SWE) of lenses in horses. Forty-six eyes of 23 horses with no evidence of ocular disease were included in this study. The horses underwent an ophthalmic examination to ensure that they were healthy. After the B-mode ultrasound examination, 2D-SWE was performed by two operators with different levels of experience in diagnostic imaging. Elastographic images were independently analyzed quantitatively by two observers by measuring the shear wave velocity (m/s) and Young's modulus (kPa). Considering both right and left eyes, the mean shear wave velocity was 4.08 ± 0.71 m/s, and the mean Young's modulus was 51.30 ± 19.02 kPa. Interoperator and intraoperator agreements were excellent. The intra-observer agreement was good, with only one value for each observer that presented statistically significant differences. No statistically significant differences were observed between the right and left eyes. The excellent reliability, reproducibility, and good repeatability between evaluators make 2D-SWE a practical and reproducible technique that can be applied in clinical settings, where different sonographers often obtain images on multiple separate occasions. Our findings support the future clinical application of 2D-SW elastography as a noninvasive imaging modality for normal lens evaluation in horses.

Veterinary Radiology & UltrasoundVol. 66(3)
University of Teramo (IT)
European Commission
Good health and well-being
Openalex Percentile: Top 14%
Veterinary Equine Medical Research
2.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.