Digitalized Thermal Inspection Method of the Low-Frequency Stimulation Pads for Preventing Low-Temperature Burn in Sensitive Skin

An accurate thermal measurement of low-frequency stimulation (LFS) pads for thermotherapy was investigated using background subtraction (BGS) methods. The safety of LFS thermal pads must be investigated to prevent low-temperature burns (LTBs), because they frequently contact the sensitive skin in neck, shoulder and abdominal regions. The thermal measurement was based on thermal imaging using the active region-of-interest (ROI) from a foreground. The shape of the LFS thermal pad consists of complicated curves, thus it is difficult to extract the foreground using conventional shapes of ROIs. We proposed the foreground extraction using background subtraction (BGS) and digital and morphological filters to time-variant thermal images. The foreground extraction was implemented using open sources and experimented for abdominal, cervical and patellar pads. The results showed that the foreground can be separated from background regardless of the size, position, orientation and shape of the pad. The thermal characteristics of the LFS thermal pads were evaluated from the complicated shapes of the foreground with high accuracy. This study demonstrated that standard deviation of pixel history (SDPH) is a simple method for the BGS, but the SDPH is useful to find the safety risk of LTBs and prevent them in advance. The results also showed that the proposed SDPH was simple but had remarkable accuracy compared with the conventional BGS methods. These BGS methods are expected to increase the reliability of products used on the human body. Further, the BGS methods can be used to inspect the temperatures of static products in industrial processes.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-05-23
DOI
https://doi.org/10.3390/bioengineering12060560
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digitalized Thermal Inspection Method of the Low-Frequency Stimulation Pads for Preventing Low-Temperature Burn in Sensitive Skin

Sang Kuy Han, Cheolwoong Ko, Jong-ik Song, Joonyoung Seo et al.
Bioengineering
Infrared Thermography in Medicine
article

Digitalized Thermal Inspection Method of the Low-Frequency Stimulation Pads for Preventing Low-Temperature Burn in Sensitive Skin

Sang Kuy Han, Cheolwoong Ko, Jong-ik Song, Joonyoung Seo, Hyung‐Tae Kim, Gi-Ho Seo
article en

Abstract

An accurate thermal measurement of low-frequency stimulation (LFS) pads for thermotherapy was investigated using background subtraction (BGS) methods. The safety of LFS thermal pads must be investigated to prevent low-temperature burns (LTBs), because they frequently contact the sensitive skin in neck, shoulder and abdominal regions. The thermal measurement was based on thermal imaging using the active region-of-interest (ROI) from a foreground. The shape of the LFS thermal pad consists of complicated curves, thus it is difficult to extract the foreground using conventional shapes of ROIs. We proposed the foreground extraction using background subtraction (BGS) and digital and morphological filters to time-variant thermal images. The foreground extraction was implemented using open sources and experimented for abdominal, cervical and patellar pads. The results showed that the foreground can be separated from background regardless of the size, position, orientation and shape of the pad. The thermal characteristics of the LFS thermal pads were evaluated from the complicated shapes of the foreground with high accuracy. This study demonstrated that standard deviation of pixel history (SDPH) is a simple method for the BGS, but the SDPH is useful to find the safety risk of LTBs and prevent them in advance. The results also showed that the proposed SDPH was simple but had remarkable accuracy compared with the conventional BGS methods. These BGS methods are expected to increase the reliability of products used on the human body. Further, the BGS methods can be used to inspect the temperatures of static products in industrial processes.

BioengineeringVol. 12(6)
Korea Institute of Industrial Technology (KR)
Openalex Percentile: Top 82%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.