Research on the method of mucosal negative pressure electrocoagulation marking under gastrointestinal endoscopy

With the development of medical equipment technology, minimally invasive surgery has become the core advancement direction in surgical treatment. There are still some issues with mucosal marking and injection under gastrointestinal endoscopy. This paper aims to study a novel negative pressure electrocoagulation marking technique. Using a negative pressure pump in conjunction with a radiofrequency energy emission platform, we compared the effects of conventional electrocoagulation marking and negative pressure electrocoagulation marking using porcine stomachs as experimental subjects. The experimental system includes a negative pressure electrocoagulation platform and a radiofrequency energy emission platform. The experimental materials are fresh porcine stomachs. Electrocoagulation marking of porcine stomach under no negative pressure and negative pressure conditions. An infrared thermal imaging camera was used to measure the temperature. The experimental results showed that the highest average temperature in the no negative pressure group was 78.2 ± 7.6°C, while in the negative pressure group it was 78.1 ± 7.9°C, with no significant difference between the two (<i>p</i> = 0.8557). During subsequent injection tests, the average burst pressure in the no negative pressure group was 66.40 ± 16.96 mmHg, while in the negative pressure group it was 83.48 ± 28.56 mmHg. The negative pressure group had a significantly higher burst pressure (<i>p</i> = 0.0135), indicating that the negative pressure electrocoagulation marking technique can significantly enhance mucosal elevation. The results suggest that the negative pressure electrocoagulation marking technique has great potential for application in gastrointestinal endoscopic surgery. It can improve the safety of the surgery without increasing thermal injury, helping to reduce the incidence of intraoperative complications.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2025-05-23
DOI
https://doi.org/10.1177/09544119251338437
Primary Topic
Dermatologic Treatments and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the method of mucosal negative pressure electrocoagulation marking under gastrointestinal endoscopy

Yu Zhou, Jie Ren, Hongrui Wang, Jiuzhou Zhao
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Dermatologic Treatments and Research
article

Research on the method of mucosal negative pressure electrocoagulation marking under gastrointestinal endoscopy

Yu Zhou, Jie Ren, Hongrui Wang, Jiuzhou Zhao
article en

Abstract

With the development of medical equipment technology, minimally invasive surgery has become the core advancement direction in surgical treatment. There are still some issues with mucosal marking and injection under gastrointestinal endoscopy. This paper aims to study a novel negative pressure electrocoagulation marking technique. Using a negative pressure pump in conjunction with a radiofrequency energy emission platform, we compared the effects of conventional electrocoagulation marking and negative pressure electrocoagulation marking using porcine stomachs as experimental subjects. The experimental system includes a negative pressure electrocoagulation platform and a radiofrequency energy emission platform. The experimental materials are fresh porcine stomachs. Electrocoagulation marking of porcine stomach under no negative pressure and negative pressure conditions. An infrared thermal imaging camera was used to measure the temperature. The experimental results showed that the highest average temperature in the no negative pressure group was 78.2 ± 7.6°C, while in the negative pressure group it was 78.1 ± 7.9°C, with no significant difference between the two (<i>p</i> = 0.8557). During subsequent injection tests, the average burst pressure in the no negative pressure group was 66.40 ± 16.96 mmHg, while in the negative pressure group it was 83.48 ± 28.56 mmHg. The negative pressure group had a significantly higher burst pressure (<i>p</i> = 0.0135), indicating that the negative pressure electrocoagulation marking technique can significantly enhance mucosal elevation. The results suggest that the negative pressure electrocoagulation marking technique has great potential for application in gastrointestinal endoscopic surgery. It can improve the safety of the surgery without increasing thermal injury, helping to reduce the incidence of intraoperative complications.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineVol. 239(6)
University of Shanghai for Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Dermatologic Treatments and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.