Crack-Based Estimation of Seismic Damage Level in Confined Masonry Walls in the Lima Metropolitan Area Using Deep Learning Techniques

Damage assessment methods fall into contact and non-contact approaches. Contact methods, like physical measurements, material sampling, and ultrasonic testing, provide detailed data but are time-consuming and require specialized equipment. In contrast, non-contact methods assess damage remotely, allowing for faster, safer, and large-scale evaluations, especially useful in post-disaster scenarios. However, there are currently no standardized non-contact methods for assessing damage levels in confined masonry walls after damaging seismic events in Peru. On the other hand, an experimental database of cyclic loading tests on confined masonry walls is available, supporting numerical simulations with calibrated mathematical models to estimate damage levels. This research extends the application of this database by analyzing the crack pattern imagery from the tested walls and correlating it with the lateral deformation (drift) to identify the damage levels. A high-accuracy crack measurement technique was developed, combining a convolutional neural network to generate a binary crack mask and a binary search algorithm to extract polylines and convert them into length measurements, achieving a detection accuracy of 78%. The measured crack patterns were normalized into an index, which was then correlated with the amplitude of the lateral deformation in each hysteretic loop. Finally, a relationship was established between drift and the damage level index. These findings contribute to the development of a rapid, non-contact damage assessment method for confined masonry walls in seismic-prone regions.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-05-23
DOI
https://doi.org/10.3390/app15115875
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Crack-Based Estimation of Seismic Damage Level in Confined Masonry Walls in the Lima Metropolitan Area Using Deep Learning Techniques

Juan J. Salinas, Edisson Alberto Moscoso Alcantara, Miguel Diaz, Italo Inocente et al.
Applied Sciences
Structural Health Monitoring Techniques
article

Crack-Based Estimation of Seismic Damage Level in Confined Masonry Walls in the Lima Metropolitan Area Using Deep Learning Techniques

Juan J. Salinas, Edisson Alberto Moscoso Alcantara, Miguel Diaz, Italo Inocente, Michel Amancio, Luis Alfonso Ureña López, Erika Flores, Sergio Isuhuaylas
article en

Abstract

Damage assessment methods fall into contact and non-contact approaches. Contact methods, like physical measurements, material sampling, and ultrasonic testing, provide detailed data but are time-consuming and require specialized equipment. In contrast, non-contact methods assess damage remotely, allowing for faster, safer, and large-scale evaluations, especially useful in post-disaster scenarios. However, there are currently no standardized non-contact methods for assessing damage levels in confined masonry walls after damaging seismic events in Peru. On the other hand, an experimental database of cyclic loading tests on confined masonry walls is available, supporting numerical simulations with calibrated mathematical models to estimate damage levels. This research extends the application of this database by analyzing the crack pattern imagery from the tested walls and correlating it with the lateral deformation (drift) to identify the damage levels. A high-accuracy crack measurement technique was developed, combining a convolutional neural network to generate a binary crack mask and a binary search algorithm to extract polylines and convert them into length measurements, achieving a detection accuracy of 78%. The measured crack patterns were normalized into an index, which was then correlated with the amplitude of the lateral deformation in each hysteretic loop. Finally, a relationship was established between drift and the damage level index. These findings contribute to the development of a rapid, non-contact damage assessment method for confined masonry walls in seismic-prone regions.

Applied SciencesVol. 15(11)
Chiba University (JP), National University of Engineering (PE)
Universidad Nacional de Ingenierias, Servicio Nacional de Capacitación para la Industria de la Construcción
Openalex Percentile: Top 88%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.