P81. The Evaluation of Skin Pigmentation Effects on Pulse Oximetry Monitoring Using a Novel Porcine Deoxygenation Model

PURPOSE: The purpose of this study was to investigate the impact of skin pigmentation on the accuracy of pulse oximetry using a modified porcine model with controlled systemic deoxygenation and alternately pigmented ears. METHODS: Two Hampshire pigs with naturally occurring oppositely pigmented ears were utilized. Pulse-oximetry (SpO2) data was continuously and simultaneously collected from each ear using research grade open data stream (Maxim-86171 pulseoximeter) and clinical standard proprietary pulse oximeters (Masimo-K181956). Starting from normoxemia, progressive hypoxemia (SaO2 60-100%) was induced by decreasing the fraction of inhaled oxygen in a stepwise manner. Arterial blood gas samples were intermittentlydrawn from an indwelling catheter, and co-oximetry was used to define the gold standard SaO2. RESULTS: During normoxemia, pulse oximetry readings were similar for both pigmented and non-pigmented ears. During hypoxemia, oximeters overestimated oxygen saturation in pigmented ears by +16% at 70% SaO2, while non-pigmented skin showed only a +1% discrepancy.This discrepancy was recapitulated in the Maxim oximetry data, where the slope of the modulation ratio (R)-vs SaO2 curve was 5.9% steeper in the non-pigmented compared to the pigmented ear. CONCLUSION: This study provides the first internally controlled animal model showing that skin pigmentation affects the accuracy of pulse oximetry, with comparable estimation of oxygen saturation between pigmented and non-pigmented skin, but overestimation in pigmented skin during hypoxemia.

Authors

Institutions

Publication Details

Journal
Plastic & Reconstructive Surgery Global Open
Published
2025-05-01
DOI
https://doi.org/10.1097/01.gox.0001114500.89892.de
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P81. The Evaluation of Skin Pigmentation Effects on Pulse Oximetry Monitoring Using a Novel Porcine Deoxygenation Model

Michael Butler, Tara Sara Saffari, Leonid Shmuylovich, Mitchell Andrew Pet et al.
Plastic & Reconstructive Surgery Global Open
Infrared Thermography in Medicine
article

P81. The Evaluation of Skin Pigmentation Effects on Pulse Oximetry Monitoring Using a Novel Porcine Deoxygenation Model

Michael Butler, Tara Sara Saffari, Leonid Shmuylovich, Mitchell Andrew Pet, Joe G. Ribaudo
article en

Abstract

PURPOSE: The purpose of this study was to investigate the impact of skin pigmentation on the accuracy of pulse oximetry using a modified porcine model with controlled systemic deoxygenation and alternately pigmented ears. METHODS: Two Hampshire pigs with naturally occurring oppositely pigmented ears were utilized. Pulse-oximetry (SpO2) data was continuously and simultaneously collected from each ear using research grade open data stream (Maxim-86171 pulseoximeter) and clinical standard proprietary pulse oximeters (Masimo-K181956). Starting from normoxemia, progressive hypoxemia (SaO2 60-100%) was induced by decreasing the fraction of inhaled oxygen in a stepwise manner. Arterial blood gas samples were intermittentlydrawn from an indwelling catheter, and co-oximetry was used to define the gold standard SaO2. RESULTS: During normoxemia, pulse oximetry readings were similar for both pigmented and non-pigmented ears. During hypoxemia, oximeters overestimated oxygen saturation in pigmented ears by +16% at 70% SaO2, while non-pigmented skin showed only a +1% discrepancy.This discrepancy was recapitulated in the Maxim oximetry data, where the slope of the modulation ratio (R)-vs SaO2 curve was 5.9% steeper in the non-pigmented compared to the pigmented ear. CONCLUSION: This study provides the first internally controlled animal model showing that skin pigmentation affects the accuracy of pulse oximetry, with comparable estimation of oxygen saturation between pigmented and non-pigmented skin, but overestimation in pigmented skin during hypoxemia.

Plastic & Reconstructive Surgery Global OpenVol. 13(S2)
Washington University in St. Louis (US)
Zero hunger
Openalex Percentile: Top 82%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

P81. The Evaluation of Skin Pigmentation Effects on Pulse Oximetry Monitoring Using a Novel Porcine Deoxygenation Model — Michael Butler, Tara Sara Saffari, et al. · Plastic & Reconstructive Surgery Global Open (2025) | TGRS Research Map | TGRS