Copper(I) Iodide–Hexamethylenetetramine Complex as Stable Scintillator for Free-Standing Flexible and High-Resolution X-ray Imaging Screens

The organo–inorganic coordination polymer Cu6I6(HMTA)2 (HMTA – hexamethylenetetramine) has been explored as a scintillator for X-ray imaging applications. This material, synthesized from readily available precursors via a scalable solution-based method, exhibits high photoluminescence quantum yield (>95%) and exceptional thermal and radiation stability. Composite scintillation screens (CSS) were fabricated by embedding Cu6I6(HMTA)2 nanoparticles into an ethylene-vinyl acetate (EVA) matrix, achieving high phosphor loading (up to 75 wt %) while maintaining mechanical flexibility. These CSS exhibited a maximum light yield of 63,500 photons/MeV and spatial resolution up to 18 lp/mm (line pairs/mm). Thin-film scintillators, produced by depositing Cu6I6(HMTA)2 on porous membranes, achieved an even higher spatial resolution of 24.5 lp/mm but showed reduced mechanical robustness. Remarkably, Cu6I6(HMTA)2-based screens demonstrated superior radiation stability, retaining 95% of their initial radioluminescence intensity after exposure to high X-ray doses (∼100 Gy). These results highlight the potential of Cu6I6(HMTA)2 as a high-performance scintillator for X-ray imaging applications.

Authors

Institutions

Publication Details

Journal
ACS Materials Letters
Published
2025-05-23
DOI
https://doi.org/10.1021/acsmaterialslett.5c00649
Citations
6
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
8.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Copper(I) Iodide–Hexamethylenetetramine Complex as Stable Scintillator for Free-Standing Flexible and High-Resolution X-ray Imaging Screens

Sergey A. Fateev, Eugene A. Goodilin, Alexey B. Tarasov, Anastasia V. Orlova et al.
6 citations
ACS Materials Letters
Medical Imaging Techniques and Applications
8.16
article

Copper(I) Iodide–Hexamethylenetetramine Complex as Stable Scintillator for Free-Standing Flexible and High-Resolution X-ray Imaging Screens

Sergey A. Fateev, Eugene A. Goodilin, Alexey B. Tarasov, Anastasia V. Orlova, Daria E. Belikova, Anna D. Riabova
article en
6 citations

Abstract

The organo–inorganic coordination polymer Cu6I6(HMTA)2 (HMTA – hexamethylenetetramine) has been explored as a scintillator for X-ray imaging applications. This material, synthesized from readily available precursors via a scalable solution-based method, exhibits high photoluminescence quantum yield (>95%) and exceptional thermal and radiation stability. Composite scintillation screens (CSS) were fabricated by embedding Cu6I6(HMTA)2 nanoparticles into an ethylene-vinyl acetate (EVA) matrix, achieving high phosphor loading (up to 75 wt %) while maintaining mechanical flexibility. These CSS exhibited a maximum light yield of 63,500 photons/MeV and spatial resolution up to 18 lp/mm (line pairs/mm). Thin-film scintillators, produced by depositing Cu6I6(HMTA)2 on porous membranes, achieved an even higher spatial resolution of 24.5 lp/mm but showed reduced mechanical robustness. Remarkably, Cu6I6(HMTA)2-based screens demonstrated superior radiation stability, retaining 95% of their initial radioluminescence intensity after exposure to high X-ray doses (∼100 Gy). These results highlight the potential of Cu6I6(HMTA)2 as a high-performance scintillator for X-ray imaging applications.

ACS Materials LettersVol. 7(7)
Lomonosov Moscow State University (RU), Moscow State University (TJ), Applied Energetics (United States) (US)
Russian Science Foundation, Lomonosov Moscow State University
Openalex Percentile: Top 2%
Medical Imaging Techniques and Applications
8.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.