Cardiac-specific troponin-I (cTnI) in a post-mortem setting

Cardiac-specific troponin (cTn) is widely used in clinical medicine to support a diagnosis of acute myocardial infarction. Several studies have explored the value of cTn testing in deceased individuals. These studies suggest that -although there are important limitations associated with its use- post-mortem cTn can be useful in selected cases. A decision for post-mortem cTn testing should however be influenced by factors that have not been explored in much detail. This includes the success rate of post-mortem cTn testing, and whether cTn levels are stable after death.Therefore, this study addresses the post-mortem availability and stability of cardiac-specific Troponin I (cTnI). Post-mortem availability was determined by analysing the success rate in 250 high-sensitivity (hs-)cTnI tests on post-mortem blood samples, and its relationship with variables such as sample location, sample type, post-mortem interval, and decomposition. Post-mortem stability was explored by comparing post-mortem cTnI levels between two samples from the same individual, taken at different times.Post-mortem hs-cTnI tests were successful in 86.4% of cases (216/250), with little effect of sex, age, or cardiopulmonary resuscitation. Visible decomposition precluded a successful test. Other variables associated with decomposition (such as increased post-mortem interval) also affected test success negatively. Our results furthermore suggest that cTnI is very unstable post-mortem, with marked differences in hs-cTnI test results between samples from the same individual. The differences were large (on average 18734 ng/L) and not unidirectional. Instability appeared to increase with larger time intervals, but the results were overall erratic and difficult to interpret.We conclude that hs-cTnI testing results are generally available in a post-mortem setting, but that testing should be performed on the earliest available blood sample. Samples from decomposed individuals should not be tested. Furthermore, the severe instability of cTnI indicates that any post-mortem hs-cTnI result must be interpreted with caution.

Authors

Institutions

Publication Details

Journal
International Journal of Legal Medicine
Published
2025-05-23
DOI
https://doi.org/10.1007/s00414-025-03526-x
Citations
1
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac-specific troponin-I (cTnI) in a post-mortem setting

Sarah Parsons, Elizabeth Sutton, Maria Pricone, Hans H. de Boer
1 citations
International Journal of Legal Medicine
Acute Myocardial Infarction Research
1.39
article

Cardiac-specific troponin-I (cTnI) in a post-mortem setting

Sarah Parsons, Elizabeth Sutton, Maria Pricone, Hans H. de Boer
article en
1 citations

Abstract

Cardiac-specific troponin (cTn) is widely used in clinical medicine to support a diagnosis of acute myocardial infarction. Several studies have explored the value of cTn testing in deceased individuals. These studies suggest that -although there are important limitations associated with its use- post-mortem cTn can be useful in selected cases. A decision for post-mortem cTn testing should however be influenced by factors that have not been explored in much detail. This includes the success rate of post-mortem cTn testing, and whether cTn levels are stable after death.Therefore, this study addresses the post-mortem availability and stability of cardiac-specific Troponin I (cTnI). Post-mortem availability was determined by analysing the success rate in 250 high-sensitivity (hs-)cTnI tests on post-mortem blood samples, and its relationship with variables such as sample location, sample type, post-mortem interval, and decomposition. Post-mortem stability was explored by comparing post-mortem cTnI levels between two samples from the same individual, taken at different times.Post-mortem hs-cTnI tests were successful in 86.4% of cases (216/250), with little effect of sex, age, or cardiopulmonary resuscitation. Visible decomposition precluded a successful test. Other variables associated with decomposition (such as increased post-mortem interval) also affected test success negatively. Our results furthermore suggest that cTnI is very unstable post-mortem, with marked differences in hs-cTnI test results between samples from the same individual. The differences were large (on average 18734 ng/L) and not unidirectional. Instability appeared to increase with larger time intervals, but the results were overall erratic and difficult to interpret.We conclude that hs-cTnI testing results are generally available in a post-mortem setting, but that testing should be performed on the earliest available blood sample. Samples from decomposed individuals should not be tested. Furthermore, the severe instability of cTnI indicates that any post-mortem hs-cTnI result must be interpreted with caution.

International Journal of Legal MedicineVol. 139(5)
Victorian Institute of Forensic Medicine (AU), Monash University (AU)
Monash University
Good health and well-being
Openalex Percentile: Top 19%
Acute Myocardial Infarction Research
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.