Material Design of Dental Implant for Minimum Stress Shielding of Bone Using Design of Experiment, Deep Learning, and Ashby Plot

Nowadays, dental implants are one of the essential treatments for human beings to maintain their chewing function and aesthetics. But after surgery, the Young modulus promotes stress shielding and stress simulation at the bone-implant contact, thus decreasing the density of the bone and, due to bone resorption, the dental implant fails. In this article, a material property is determined using simulation in Ansys software and using Design of Experiments (DoE) Informed Deep Learning model, which is generated for minimum stress shielding. Ashby plot is used to determine the best possible dental implant material in which five materials are obtained. Titanium and ceramics are functional in medical fields, while steels are not functional due to biocompatibility issues. However, carbon fiber-reinforced polymer (CFRP) is biocompatible and excellent for dental implants, but needs manufacturing attention. Nickel alloys can also be used for dental implants, however, their biocompatibility and technical difficulties need to be studied.

Authors

Institutions

Publication Details

Journal
Journal of Long-Term Effects of Medical Implants
Published
2025-01-01
DOI
https://doi.org/10.1615/jlongtermeffmedimplants.2025051075
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Material Design of Dental Implant for Minimum Stress Shielding of Bone Using Design of Experiment, Deep Learning, and Ashby Plot

Sambhrant Srivastava, Vijay Kumar, Ashok Kumar Yadav, Saroj Kumar Sarangi et al.
Journal of Long-Term Effects of Medical Implants
Medical Imaging and Analysis
article

Material Design of Dental Implant for Minimum Stress Shielding of Bone Using Design of Experiment, Deep Learning, and Ashby Plot

Sambhrant Srivastava, Vijay Kumar, Ashok Kumar Yadav, Saroj Kumar Sarangi, Tahir Ahmad
article en

Abstract

Nowadays, dental implants are one of the essential treatments for human beings to maintain their chewing function and aesthetics. But after surgery, the Young modulus promotes stress shielding and stress simulation at the bone-implant contact, thus decreasing the density of the bone and, due to bone resorption, the dental implant fails. In this article, a material property is determined using simulation in Ansys software and using Design of Experiments (DoE) Informed Deep Learning model, which is generated for minimum stress shielding. Ashby plot is used to determine the best possible dental implant material in which five materials are obtained. Titanium and ceramics are functional in medical fields, while steels are not functional due to biocompatibility issues. However, carbon fiber-reinforced polymer (CFRP) is biocompatible and excellent for dental implants, but needs manufacturing attention. Nickel alloys can also be used for dental implants, however, their biocompatibility and technical difficulties need to be studied.

Journal of Long-Term Effects of Medical ImplantsVol. 35(4)
National Institute of Technology Patna (IN)
Openalex Percentile: Top 89%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Material Design of Dental Implant for Minimum Stress Shielding of Bone Using Design of Experiment, Deep Learning, and Ashby Plot — Sambhrant Srivastava, Vijay Kumar, et al. · Journal of Long-Term Effects of Medical Implants (2025) | TGRS Research Map | TGRS