An eco-friendly bioanalytical RP-HPLC method coupled with fluorescence detection for simultaneous estimation of felodipine and metoprolol

An ecofriendly, sensitive, selective, precise, and accurate HPLC method with fluorescence detection (FD) has been developed and validated for simultaneous determination of two hypertensive drugs, felodipine and metoprolol in their pure samples, combined pharmaceutical dosage form and in spiked human plasma. Separation was carried out on Inertsil C<sub>18</sub> column (150 mm × 4.6 ID; Particle size 5 µm) and a mobile phase composed of ethanol and 30mM potassium dihydrogen phosphate buffer, adjusted to pH 2.5 using ortho-phosphoric acid (40:60, v/v) was used. A constant flow rate of 1.0 mL/min at an ambient temperature was adopted. Method validation was performed according to the ICH Q2 R2 and bioanalytical method validation was done according to FDA guidelines for determination of both drugs simultaneously in biological matrices. The method demonstrated excellent linearity over the concentration range of 0.01-1.00 µg/mL and 0.003-1.00 µg/mL that were selected with accordance to the C<sub>max</sub> of both drugs with a correlation coefficient (r<sup>2</sup>) of 0.9998 and 0.9999 for felodipine and metoprolol, respectively in human plasma. The intra-day and inter-day precision were ≤ 2% in their pure forms and in spiked human plasma, and the accuracy was within ± 2% of the nominal concentration for both drugs in their pure forms and within ± 10% of the nominal concentration in human plasma. A statistical comparison was conducted between the proposed method and the reported method; it showed no significant difference between both methods regarding both accuracy and precision. The proposed method proved to be eco-friendly with three green assessment tools (AGREE calculator, MoGAPI, RGBfast study).

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2025-05-23
DOI
https://doi.org/10.1186/s13065-025-01507-0
Citations
4
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
3.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An eco-friendly bioanalytical RP-HPLC method coupled with fluorescence detection for simultaneous estimation of felodipine and metoprolol

Maha A. Hegazy, Amira Kessiba, Lubna Kormod, Ahmed Emad El Gendy et al.
4 citations
BMC Chemistry
Analytical Methods in Pharmaceuticals
3.01
article

An eco-friendly bioanalytical RP-HPLC method coupled with fluorescence detection for simultaneous estimation of felodipine and metoprolol

Maha A. Hegazy, Amira Kessiba, Lubna Kormod, Ahmed Emad El Gendy, Mariam Wasim Beniamin
article en
4 citations

Abstract

An ecofriendly, sensitive, selective, precise, and accurate HPLC method with fluorescence detection (FD) has been developed and validated for simultaneous determination of two hypertensive drugs, felodipine and metoprolol in their pure samples, combined pharmaceutical dosage form and in spiked human plasma. Separation was carried out on Inertsil C<sub>18</sub> column (150 mm × 4.6 ID; Particle size 5 µm) and a mobile phase composed of ethanol and 30mM potassium dihydrogen phosphate buffer, adjusted to pH 2.5 using ortho-phosphoric acid (40:60, v/v) was used. A constant flow rate of 1.0 mL/min at an ambient temperature was adopted. Method validation was performed according to the ICH Q2 R2 and bioanalytical method validation was done according to FDA guidelines for determination of both drugs simultaneously in biological matrices. The method demonstrated excellent linearity over the concentration range of 0.01-1.00 µg/mL and 0.003-1.00 µg/mL that were selected with accordance to the C<sub>max</sub> of both drugs with a correlation coefficient (r<sup>2</sup>) of 0.9998 and 0.9999 for felodipine and metoprolol, respectively in human plasma. The intra-day and inter-day precision were ≤ 2% in their pure forms and in spiked human plasma, and the accuracy was within ± 2% of the nominal concentration for both drugs in their pure forms and within ± 10% of the nominal concentration in human plasma. A statistical comparison was conducted between the proposed method and the reported method; it showed no significant difference between both methods regarding both accuracy and precision. The proposed method proved to be eco-friendly with three green assessment tools (AGREE calculator, MoGAPI, RGBfast study).

BMC ChemistryVol. 19(1)
Cairo University (EG), Misr International University (EG)
Science and Technology Development Fund
Responsible consumption and production
Openalex Percentile: Top 9%
Analytical Methods in Pharmaceuticals
3.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.