Daily Peak Load Forecasting At PT. PLN Uses Anfis(Adaptive Neuro-Fuzzy Inference System)

The demand for electrical energy continues to rise with the progression of time. This growth must be matched by a reliable and cost-effective supply of electricity, requiring power systems that are both dependable and economical. Since the amount of electricity consumed by users cannot be precisely predicted, balancing generation with consumption necessitates accurate electrical load forecasting. This study focuses on load forecasting using the Adaptive Neuro-Fuzzy Inference System (ANFIS) method. The forecast developed targets daily peak loads, which fall under short-term load forecasting. The data used for this forecasting consists of historical daily peak loads from January 1, 2017, to June 9, 2022. The forecasting process involves parameters such as radius, squash factor, accept ratio, reject ratio, and epoch. The forecast accuracy is evaluated using the Mean Absolute Percentage Error (MAPE) metric. The results are then compared with PLN’s load forecasting, which employs the load coefficient method. The ANFIS-based forecasting achieved a MAPE of 1.879%, using networks Jaringan_24 and Jaringan_25. This MAPE value is slightly lower than PLN’s load forecasting MAPE of 1.917%, indicating better accuracy by the ANFIS method.

Authors

Institutions

Publication Details

Journal
Journal of Scientific Interdisciplinary
Published
2025-05-24
DOI
https://doi.org/10.62504/jis1250
Primary Topic
Management and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Daily Peak Load Forecasting At PT. PLN Uses Anfis(Adaptive Neuro-Fuzzy Inference System)

Susatyo Handoko, Karnoto Karnoto
1 links
Journal of Scientific Interdisciplinary
Management and Optimization Techniques
article

Daily Peak Load Forecasting At PT. PLN Uses Anfis(Adaptive Neuro-Fuzzy Inference System)

Susatyo Handoko, Karnoto Karnoto
article en

Abstract

The demand for electrical energy continues to rise with the progression of time. This growth must be matched by a reliable and cost-effective supply of electricity, requiring power systems that are both dependable and economical. Since the amount of electricity consumed by users cannot be precisely predicted, balancing generation with consumption necessitates accurate electrical load forecasting. This study focuses on load forecasting using the Adaptive Neuro-Fuzzy Inference System (ANFIS) method. The forecast developed targets daily peak loads, which fall under short-term load forecasting. The data used for this forecasting consists of historical daily peak loads from January 1, 2017, to June 9, 2022. The forecasting process involves parameters such as radius, squash factor, accept ratio, reject ratio, and epoch. The forecast accuracy is evaluated using the Mean Absolute Percentage Error (MAPE) metric. The results are then compared with PLN’s load forecasting, which employs the load coefficient method. The ANFIS-based forecasting achieved a MAPE of 1.879%, using networks Jaringan_24 and Jaringan_25. This MAPE value is slightly lower than PLN’s load forecasting MAPE of 1.917%, indicating better accuracy by the ANFIS method.

Journal of Scientific InterdisciplinaryVol. 2(3)
Diponegoro University (ID)
Openalex Percentile: Top 83%
Management and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.