The Interplay of Time and Angle with the Incidence of Pneumothorax in Computed Tomography-Guided Lung Biopsy

Pneumothorax remains one of the most common complications of computed tomography (CT)-guided lung biopsy, highlighting the importance of investigating contributing factors. This study assessed the interplay between the needle-pleura angle and the biopsy needle traversal duration (NTD) through the lung parenchyma during CT-guided lung biopsies that resulted in pneumothorax.In this retrospective study, 96 patients underwent CT-guided lung biopsies. The minimum delta (δmin) was calculated as the absolute value of the difference between a 90° angle and the measured angles of the needle with respect to the pleura, and correlations with the occurrence of pneumothorax were analyzed. The NTD was recorded from the moment of needle puncture through the pleura until needle retraction. Patients with pneumothorax were grouped on the basis of NTD: < or > 6 minutes. A multivariate analysis was conducted, comparing four patient groups with and without pneumothorax.6 out of 96 patients undergoing CT-guided lung biopsies were excluded because of predefined exclusion criteria. 22 patients experienced postprocedural pneumothorax-6/22 patients had δmin > 10° with NTD > 6 minutes, 5/22 had δmin < 10° with NTD < 6 minutes, 2/22 had δmin > 10° with NTD < 6 minutes, and 9/22 had δmin < 10° with NTD > 6 minutes. Overall, 14.7% of patients with δmin < 10° and NTD < 6 minutes experienced pneumothorax compared with 33.3% of patients with δmin > 10° with NTD > 6 minutes.Optimizing the needle-pleura angle and NTD during a CT-guided lung biopsy can reduce the risk of pneumothorax. · Pneumothorax is the most common complication of lung biopsies.. · Needle angle und needle-traversal duration can affect the incidence of pneumothorax.. · Needle-pleura angle and the needle-traversal duration can reduce the risk of pneumothorax.. · Maalouf N, Abou Mrad M, Benayed R et al. The Interplay of Time and Angle with the Incidence of Pneumothorax in Computed Tomography-Guided Lung Biopsy. Rofo 2025; DOI 10.1055/a-2594-7226.

Authors

Publication Details

Journal
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Published
2025-05-23
DOI
https://doi.org/10.1055/a-2594-7226
Citations
1
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Interplay of Time and Angle with the Incidence of Pneumothorax in Computed Tomography-Guided Lung Biopsy

Nour Maalouf, Mazen Abou Mrad, Jonas Apitzsch, Rosa Alba Pugliesi et al.
1 citations
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Lung Cancer Diagnosis and Treatment
1.52
article

The Interplay of Time and Angle with the Incidence of Pneumothorax in Computed Tomography-Guided Lung Biopsy

Nour Maalouf, Mazen Abou Mrad, Jonas Apitzsch, Rosa Alba Pugliesi, Roua BenAyed
article en
1 citations

Abstract

Pneumothorax remains one of the most common complications of computed tomography (CT)-guided lung biopsy, highlighting the importance of investigating contributing factors. This study assessed the interplay between the needle-pleura angle and the biopsy needle traversal duration (NTD) through the lung parenchyma during CT-guided lung biopsies that resulted in pneumothorax.In this retrospective study, 96 patients underwent CT-guided lung biopsies. The minimum delta (δmin) was calculated as the absolute value of the difference between a 90° angle and the measured angles of the needle with respect to the pleura, and correlations with the occurrence of pneumothorax were analyzed. The NTD was recorded from the moment of needle puncture through the pleura until needle retraction. Patients with pneumothorax were grouped on the basis of NTD: < or > 6 minutes. A multivariate analysis was conducted, comparing four patient groups with and without pneumothorax.6 out of 96 patients undergoing CT-guided lung biopsies were excluded because of predefined exclusion criteria. 22 patients experienced postprocedural pneumothorax-6/22 patients had δmin > 10° with NTD > 6 minutes, 5/22 had δmin < 10° with NTD < 6 minutes, 2/22 had δmin > 10° with NTD < 6 minutes, and 9/22 had δmin < 10° with NTD > 6 minutes. Overall, 14.7% of patients with δmin < 10° and NTD < 6 minutes experienced pneumothorax compared with 33.3% of patients with δmin > 10° with NTD > 6 minutes.Optimizing the needle-pleura angle and NTD during a CT-guided lung biopsy can reduce the risk of pneumothorax. · Pneumothorax is the most common complication of lung biopsies.. · Needle angle und needle-traversal duration can affect the incidence of pneumothorax.. · Needle-pleura angle and the needle-traversal duration can reduce the risk of pneumothorax.. · Maalouf N, Abou Mrad M, Benayed R et al. The Interplay of Time and Angle with the Incidence of Pneumothorax in Computed Tomography-Guided Lung Biopsy. Rofo 2025; DOI 10.1055/a-2594-7226.

RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden VerfahrenVol. 198(03)
Reduced inequalities
Openalex Percentile: Top 18%
Lung Cancer Diagnosis and Treatment
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.