Examination and Simulation of a High-Cycle Fatigue Tester for Accelerated Stress Testing with Simplified Cantilever Specimens for Fracture-Mechanical Interface Characterization

We present a high-cycle fatigue (HCF) test designed for the accelerated stress testing of metallization layers and bi-material interfaces in microelectronic packages under controlled periodic displacement amplitudes and isothermal conditions. The primary objective of this study is to examine the delamination of bi-material interfaces. The samples utilized for testing are manufactured on a magnetic steel substrate, employing the same processes employed in the production of the microelectronic packages to be tested. A range of methodologies have been developed for sample preparation. To excite the sample, we use magnetic actuation. The sample is subjected to oscillation from a cyclic load, allowing for several million oscillation cycles in a short time. The change in crack length can be determined using a stiffness method by capturing changes in the beam's vibration spectrum. Besides this method of crack measurement, crack progression can also be calculated from the measurement of the bending line. This stress method enables the rapid testing of the integrity of microelectronic components under harsh conditions.

Authors

Institutions

Publication Details

Published
2025-04-06
DOI
https://doi.org/10.1109/eurosime65125.2025.11006621
Primary Topic
Fatigue and fracture mechanics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Examination and Simulation of a High-Cycle Fatigue Tester for Accelerated Stress Testing with Simplified Cantilever Specimens for Fracture-Mechanical Interface Characterization

David C. Walther, Bernhard Wunderle, J. Arnold, Arash Mohammadi
Fatigue and fracture mechanics
article

Examination and Simulation of a High-Cycle Fatigue Tester for Accelerated Stress Testing with Simplified Cantilever Specimens for Fracture-Mechanical Interface Characterization

David C. Walther, Bernhard Wunderle, J. Arnold, Arash Mohammadi
article en

Abstract

We present a high-cycle fatigue (HCF) test designed for the accelerated stress testing of metallization layers and bi-material interfaces in microelectronic packages under controlled periodic displacement amplitudes and isothermal conditions. The primary objective of this study is to examine the delamination of bi-material interfaces. The samples utilized for testing are manufactured on a magnetic steel substrate, employing the same processes employed in the production of the microelectronic packages to be tested. A range of methodologies have been developed for sample preparation. To excite the sample, we use magnetic actuation. The sample is subjected to oscillation from a cyclic load, allowing for several million oscillation cycles in a short time. The change in crack length can be determined using a stiffness method by capturing changes in the beam's vibration spectrum. Besides this method of crack measurement, crack progression can also be calculated from the measurement of the bending line. This stress method enables the rapid testing of the integrity of microelectronic components under harsh conditions.

Chemnitz University of Technology (DE), Fraunhofer Institute for Electronic Nano Systems (DE)
Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 87%
Fatigue and fracture mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.