Rapid detection of accidental hand exposure using radiophotoluminescence glass (FD-7) and an overhead scanning system

Workers who use high-intensity radiation sources on a daily basis are at risk of accidentally exposing their fingers to high levels of radiation, which can cause acute effects such as skin damage. For the prompt detection of such unexpected severe exposure, we attempted to use the radiochromic reaction of radiophotoluminscence (RPL) glass that can be worn on the fingers with a common overhead scanning system. A plate-shaped RPL glass (FD-7) with the size of 8.0 × 8.0 × 1.5 mm 3 used in a commercially available ring-type glass dosimeter was irradiated with X-rays (160 kV, 6.3 mA) at 80–400 Gy, for which RPL measurements were difficult. Radiochromic reactions of FD-7 were visually confirmed on a tracing light board, and the RGB images captured at certain time intervals using an overhead scanner (OHS) were analyzed using image processing software (ImageJ). In addition, time changes in the post-irradiation absorbance spectra were measured using a UV-visible spectrophotometer. The post-irradiation brownish coloration of FD-7 was detected by the naked eye at all doses (≥80 Gy). From the inverted images acquired by the OHS, the color intensity of the blue channel showed the most preferable dose response covering the target dose range. Interestingly, the blue color intensity stabilized immediately after X-ray irradiation without a preheating procedure, which is generally required in RPL glass dosimetry. The spectrophotometry data confirmed the results obtained using the overhead scanning system; the absorbance in the blue color range (430-490 nm) slightly reduced during the period of post-irradiation RPL build-up. These findings highlight the practical advantages of this novel method for monitoring hand exposure. • An approach for rapidly detecting high-dose hand exposure using RPL-glass (FD-7) was proposed. • FD-7 plates irradiated with up to 400 Gy X-rays were scanned using an overhead scanning system. • The blue channel intensity of the scanned image showed a good dose response without time buildup. • Photospectrometry data confirmed the findings obtained using this novel scanning system.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2025-05-23
DOI
https://doi.org/10.1016/j.radmeas.2025.107468
Citations
3
Primary Topic
Bacillus and Francisella bacterial research
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid detection of accidental hand exposure using radiophotoluminescence glass (FD-7) and an overhead scanning system

Yasuhiro Koguchi, Sophia E. Welti, Hiroshi Yasuda, Yuka Yanagida et al.
3 citations
Radiation Measurements
Bacillus and Francisella bacterial research
2.42
article

Rapid detection of accidental hand exposure using radiophotoluminescence glass (FD-7) and an overhead scanning system

Yasuhiro Koguchi, Sophia E. Welti, Hiroshi Yasuda, Yuka Yanagida, Ryuto Inobe
article en
3 citations

Abstract

Workers who use high-intensity radiation sources on a daily basis are at risk of accidentally exposing their fingers to high levels of radiation, which can cause acute effects such as skin damage. For the prompt detection of such unexpected severe exposure, we attempted to use the radiochromic reaction of radiophotoluminscence (RPL) glass that can be worn on the fingers with a common overhead scanning system. A plate-shaped RPL glass (FD-7) with the size of 8.0 × 8.0 × 1.5 mm 3 used in a commercially available ring-type glass dosimeter was irradiated with X-rays (160 kV, 6.3 mA) at 80–400 Gy, for which RPL measurements were difficult. Radiochromic reactions of FD-7 were visually confirmed on a tracing light board, and the RGB images captured at certain time intervals using an overhead scanner (OHS) were analyzed using image processing software (ImageJ). In addition, time changes in the post-irradiation absorbance spectra were measured using a UV-visible spectrophotometer. The post-irradiation brownish coloration of FD-7 was detected by the naked eye at all doses (≥80 Gy). From the inverted images acquired by the OHS, the color intensity of the blue channel showed the most preferable dose response covering the target dose range. Interestingly, the blue color intensity stabilized immediately after X-ray irradiation without a preheating procedure, which is generally required in RPL glass dosimetry. The spectrophotometry data confirmed the results obtained using the overhead scanning system; the absorbance in the blue color range (430-490 nm) slightly reduced during the period of post-irradiation RPL build-up. These findings highlight the practical advantages of this novel method for monitoring hand exposure. • An approach for rapidly detecting high-dose hand exposure using RPL-glass (FD-7) was proposed. • FD-7 plates irradiated with up to 400 Gy X-rays were scanned using an overhead scanning system. • The blue channel intensity of the scanned image showed a good dose response without time buildup. • Photospectrometry data confirmed the findings obtained using this novel scanning system.

Radiation MeasurementsVol. 186
Hiroshima University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 12%
Bacillus and Francisella bacterial research
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.