Evaluating compliance in three-dimensional-printed polymeric vascular grafts compared to human arteries and commercial grafts in a mock circulation loop compliance in three-dimensional-printed polymeric vascular grafts

Compliance mismatch between native arteries and prosthetic grafts contribute to complications such as neointimal hyperplasia and pseudoaneurysms, leading to reduced graft patency. Three-dimensional (3D) printing offers a promising solution by flexibly customizing mechanical properties using elastic polymers. This study investigates whether 3D-printed polymeric grafts can better replicate native arterial compliance compared with commercial prosthetic grafts. We conducted compliance tests on human aortoiliac arteries, polytetrafluoroethylene (PTFE) grafts, Dacron grafts, and 3D-printed arteries with BioMed Elastic Resin within a mock circulation loop. All samples shared controlled geometry and were tested under the same physiological flow conditions. Pressure waveforms and key hemodynamic parameters were recorded and analyzed. The 3D-printed graft demonstrated a compliance of 0.49 cm<sup>3</sup>/mmHg, more closely matching the human artery than PTFE (0.38 cm<sup>3</sup>/mmHg) and Dacron (0.45 cm<sup>3</sup>/mmHg). Its mean arterial pressure (82 ± 0.6 mmHg) and peak pressure (40 ± 0.7 mmHg) in the flow loop also aligned more closely with the native artery compared with conventional grafts. Standard prosthetic graft materials have remained relatively static, whereas there has been immense advancement in new polymer technology. These polymers can match the compliance of native vessels, theoretically reducing complications associated with traditional grafts, and future work should investigate their biocompatibility, durability, and clinical feasibility.

Authors

Institutions

Publication Details

Journal
JVS Vascular Science
Published
2025-01-01
DOI
https://doi.org/10.1016/j.jvssci.2025.100291
Citations
1
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating compliance in three-dimensional-printed polymeric vascular grafts compared to human arteries and commercial grafts in a mock circulation loop compliance in three-dimensional-printed polymeric vascular grafts

Alan P. Sawchuk, V.K. Tewari, Huidan Yu, Weichen Hong et al.
1 citations
JVS Vascular Science
Electrospun Nanofibers in Biomedical Applications
0.60
article

Evaluating compliance in three-dimensional-printed polymeric vascular grafts compared to human arteries and commercial grafts in a mock circulation loop compliance in three-dimensional-printed polymeric vascular grafts

Alan P. Sawchuk, V.K. Tewari, Huidan Yu, Weichen Hong, Jun Chen
article en
1 citations

Abstract

Compliance mismatch between native arteries and prosthetic grafts contribute to complications such as neointimal hyperplasia and pseudoaneurysms, leading to reduced graft patency. Three-dimensional (3D) printing offers a promising solution by flexibly customizing mechanical properties using elastic polymers. This study investigates whether 3D-printed polymeric grafts can better replicate native arterial compliance compared with commercial prosthetic grafts. We conducted compliance tests on human aortoiliac arteries, polytetrafluoroethylene (PTFE) grafts, Dacron grafts, and 3D-printed arteries with BioMed Elastic Resin within a mock circulation loop. All samples shared controlled geometry and were tested under the same physiological flow conditions. Pressure waveforms and key hemodynamic parameters were recorded and analyzed. The 3D-printed graft demonstrated a compliance of 0.49 cm<sup>3</sup>/mmHg, more closely matching the human artery than PTFE (0.38 cm<sup>3</sup>/mmHg) and Dacron (0.45 cm<sup>3</sup>/mmHg). Its mean arterial pressure (82 ± 0.6 mmHg) and peak pressure (40 ± 0.7 mmHg) in the flow loop also aligned more closely with the native artery compared with conventional grafts. Standard prosthetic graft materials have remained relatively static, whereas there has been immense advancement in new polymer technology. These polymers can match the compliance of native vessels, theoretically reducing complications associated with traditional grafts, and future work should investigate their biocompatibility, durability, and clinical feasibility.

JVS Vascular ScienceVol. 6
Purdue University West Lafayette (US), Indiana University School of Medicine, Indiana University – Purdue University Indianapolis (US)
Openalex Percentile: Top 34%
Electrospun Nanofibers in Biomedical Applications
0.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.