Efficiency Testing of Pelton Turbines with Artificial Defects—Part 1: Buckets

Pelton turbines are susceptible to hydro-abrasive erosion from sediment-laden flows, resulting in a progressive loss of efficiency. Typical defect classes can be derived from the analysis of such damage observed in hydropower plants. A systematic strategy was developed to investigate the effect of locally damaged Pelton runners on the efficiency in laboratory tests using a model turbine. For this purpose, nine identical runners were fabricated and machined with an increasing size, depth, or number of different artificial defect types, such as splitter, rounded or sharp-edged, defects at the cutout, defects in the bucket base, and added ripples on the bucket sides. The processing steps, the efficiency measurement, and the extracted slopes of the efficiency drops are discussed in detail. The main findings are that the efficiency losses due to the various defects increase in a good approximation linearly with the machining depth and that the individual defect types can be superimposed. Defects at the splitter, bucket base, and bucket side dominate the losses at partial load of the turbine, while those at the cutout dominate at full load. Based on the results of this measurement campaign, power plant operators can estimate the magnitude of efficiency losses in their plant.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-23
DOI
https://doi.org/10.3390/en18112716
Citations
1
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficiency Testing of Pelton Turbines with Artificial Defects—Part 1: Buckets

Ernesto Casartelli, Thomas Staubli, Florian Fahrni
1 citations
Energies
Engineering Diagnostics and Reliability
0.86
article

Efficiency Testing of Pelton Turbines with Artificial Defects—Part 1: Buckets

Ernesto Casartelli, Thomas Staubli, Florian Fahrni
article en
1 citations

Abstract

Pelton turbines are susceptible to hydro-abrasive erosion from sediment-laden flows, resulting in a progressive loss of efficiency. Typical defect classes can be derived from the analysis of such damage observed in hydropower plants. A systematic strategy was developed to investigate the effect of locally damaged Pelton runners on the efficiency in laboratory tests using a model turbine. For this purpose, nine identical runners were fabricated and machined with an increasing size, depth, or number of different artificial defect types, such as splitter, rounded or sharp-edged, defects at the cutout, defects in the bucket base, and added ripples on the bucket sides. The processing steps, the efficiency measurement, and the extracted slopes of the efficiency drops are discussed in detail. The main findings are that the efficiency losses due to the various defects increase in a good approximation linearly with the machining depth and that the individual defect types can be superimposed. Defects at the splitter, bucket base, and bucket side dominate the losses at partial load of the turbine, while those at the cutout dominate at full load. Based on the results of this measurement campaign, power plant operators can estimate the magnitude of efficiency losses in their plant.

EnergiesVol. 18(11)
Lucerne University of Applied Sciences and Arts (CH)
Bundesamt für Energie
Openalex Percentile: Top 30%
Engineering Diagnostics and Reliability
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.