Phase sensitivity of a modified Grover-Michelson interferometer

Power recycling techniques are usually used to improve the phase sensitivity of interferometers by reusing the input light energy, and can beat the shot noise level. Recent studies have demonstrated that the phase sensitivity of the interferometer is significantly improved via the addition of a recycling cavity, that is, coupling the interferometer with an external optical device. This study reviewed such types of interferometers named Grover-Michelson interferometers (GMI), and discusses their phase sensitivity with coherent states as inputs. Subsequently, a detailed comparison in terms of the scale of 1/ N and the standard quantum limit (SQL) is presented. The results demonstrate that the phase sensitivity of GMI improved owing to the power recycling and exceeded the value of 1/ N . Further, we proposed a modified Grover-Michelson interferometer (MGMI) with two input ports and examined its phase sensitivity with single photon or coherent states, respectively. Finally, in the presence of photon losses, we investigated the phase sensitivity of the four different interferometers, including MGMI, GMI, Mach-Zehnder interferometer (MZI), and SU(1,1) interferometer (SU(1,1)I), and conducted detailed comparisons. The results of this study indicated that the phase sensitivity of MGMI significantly improved owing to the increase in input energy, and MGMI exhibited the strongest robustness against photon number loss. These theoretical results are expected to facilitate improvements in interferometers and the detection of weak signals.

Authors

Institutions

Publication Details

Journal
Optics Continuum
Published
2025-05-23
DOI
https://doi.org/10.1364/optcon.546829
Citations
1
Primary Topic
Optical Polarization and Ellipsometry
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase sensitivity of a modified Grover-Michelson interferometer

Chaoping Wei, Qi Li, C. Xu
1 citations
Optics Continuum
Optical Polarization and Ellipsometry
0.67
article

Phase sensitivity of a modified Grover-Michelson interferometer

Chaoping Wei, Qi Li, C. Xu
article en
1 citations

Abstract

Power recycling techniques are usually used to improve the phase sensitivity of interferometers by reusing the input light energy, and can beat the shot noise level. Recent studies have demonstrated that the phase sensitivity of the interferometer is significantly improved via the addition of a recycling cavity, that is, coupling the interferometer with an external optical device. This study reviewed such types of interferometers named Grover-Michelson interferometers (GMI), and discusses their phase sensitivity with coherent states as inputs. Subsequently, a detailed comparison in terms of the scale of 1/ N and the standard quantum limit (SQL) is presented. The results demonstrate that the phase sensitivity of GMI improved owing to the power recycling and exceeded the value of 1/ N . Further, we proposed a modified Grover-Michelson interferometer (MGMI) with two input ports and examined its phase sensitivity with single photon or coherent states, respectively. Finally, in the presence of photon losses, we investigated the phase sensitivity of the four different interferometers, including MGMI, GMI, Mach-Zehnder interferometer (MZI), and SU(1,1) interferometer (SU(1,1)I), and conducted detailed comparisons. The results of this study indicated that the phase sensitivity of MGMI significantly improved owing to the increase in input energy, and MGMI exhibited the strongest robustness against photon number loss. These theoretical results are expected to facilitate improvements in interferometers and the detection of weak signals.

Optics ContinuumVol. 4(6)
Jiangxi Academy of Sciences (CN)
Openalex Percentile: Top 31%
Optical Polarization and Ellipsometry
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.