Impact of different type of anesthesia on acute efficacy of pulmonary vein isolation by means of very high power short duration radiofrequency ablation
Abstract Background Different type of anesthesia can be adopted during pulmonary vein isolation (PVI). Although general anesthesia (GA) may improve catheter stability however many EP labs lack of anesthesiologists availability, thus a conscious/deep sedation is adopted. Moreover, in the very high power short duration (vHPSD) ablation era, there are no clear evidence of the superiority of one over the other. Purpose We sought to investigate in a large cohort of atrial fibrillation (AF) patients the impact of different type of anesthesia on the procedural outcomes. Methods The AIR HPSD Registry is a multicentric study including AF patients undergoing their first PVI procedure by mean of the QDOT Micro catheter across 22 European centers. The QDOT Micro catheter (Biosense Webster, Inc CA) enables the ablation in the Qmode+ modality (90 W for 4 sec) and/or in the Qmode modality, 50 W ablation index (AI)-guided. The ablation modality (hybrid/ Qmode+) and the type of anesthesia were left to operators’ preference. Results Overall, 917 patients have been enrolled, 72% males, 70% had paroxysmal AF, the mean age was 62±10 years. Pulmonary vein isolation was reached in 100% regardless of the ablation modality. The rate of first pass isolation (FPI) was similar between patients ablated under general anesthesia (GA) and those ablated under conscious/deep sedation (76% vs. 75.5%, p=ns). When dividing the patients based on the ablation modality, in the Qmode+ group there was a trend toward higher rate of FPI in the GA group (79% vs. 73%; p=0.058), conversely no differences were found in the hybrid group. The procedural time was shorter in the GA group (97±36 vs. 106±42 min, p<0.01) whereas the fluoroscopy time was similar between the two groups (315±467 min vs. 339±409 sec, p=ns). Furthermore, No differences in the rate of complications were observed between the two groups (0% vs. 1,4%, p=ns). Conclusions The type of anesthesia doesn’t impact on the procedural efficacy and safety of the vHPSD ablation, however the use of GA shortens the overall procedural time.
Authors
- Luca Rossi (ORCID: https://orcid.org/0000-0003-3288-9134)
- Piotr Lodziński
- Antoine Lepillier (ORCID: https://orcid.org/0000-0001-9757-362X)
- Maurizio Russo
- Aniello Russo (ORCID: https://orcid.org/0000-0003-3651-8146)
- F Solimene
- Paolo Compagnucci (ORCID: https://orcid.org/0000-0003-1924-6548)
- R. Mantovan (ORCID: https://orcid.org/0000-0002-9353-4137)
- Teresa Strisciuglio (ORCID: https://orcid.org/0000-0001-5928-1669)
- G Stabile
- Ki‐Woon Kang (ORCID: https://orcid.org/0000-0002-1361-0022)
- Sarah Zeriouh (ORCID: https://orcid.org/0009-0003-3832-000X)
- Sara Poggi (ORCID: https://orcid.org/0009-0002-5029-5081)
- Kristine Jubele (ORCID: https://orcid.org/0000-0002-6776-8407)
- Vincenzo Schillaci
Institutions
- Medical University of Warsaw (PL)
- Royal Papworth Hospital (GB)
- Cambridge University Hospitals NHS Foundation Trust (GB)
- Ospedale San Filippo Neri (IT)
- Pauls Stradiņš Clinical University Hospital (LV)
- Ospedali Riuniti di Ancona (IT)
- Clinica Mediterranea (IT)
- Guglielmo da Saliceto Hospital (IT)
- Centre Cardiologique du Nord (FR)
- Hospital Montecelo (ES)
- University of Naples Federico II (IT)
Publication Details
- Journal
- EP Europace
- Published
- 2025-05-01
- DOI
- https://doi.org/10.1093/europace/euaf085.456
- Primary Topic
- Cardiac Arrhythmias and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00