Impact of catheter type on lesion dimensions in focal-bipolar pulsed field ablation

Abstract Introduction Pulsed field ablation (PFA) is a novel technique for pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF). However, the impact of electrode type on lesion formation at fixed PFA parameters remains unknown. This study investigated differences in lesion characteristics when using a 4 mm non-irrigated catheter versus an open-irrigated flexible-tip catheter in focal-bipolar PFA in a vegetable model. Methods PFA applications were performed in a potato model using a purpose-made PFA generator, applying both a solid-tip 4 mm non-irrigated catheter and an open-irrigated flexible-tip catheter under identical energy delivery parameters. After electroporation, potatoes were stained with triphenyltetrazolium chloride (TTC) to visualize lesion boundaries. Depth, diameter, and volume of the irreversibly electroporated zones were measured to assess the impact of each electrode type. Results A total of fifty PFA applications were performed—25 with the 4 mm non-irrigated catheter and 25 with the open-irrigated flexible-tip catheter. The depth of the irreversible electroporation zone was significantly greater with the 4 mm non-irrigated catheter than with the irrigated electrode (1.7±0.5 mm vs. 1.4±0.7 mm, p=0.03). The diameter of irreversible lesions created with the 4 mm electrode was 7±1 mm, compared to 6±1 mm with the irrigated electrode (p=0.001), resulting in a total lesion volume of 185 mm³ versus 120 mm³, respectively (p=0.0008). Conclusion The use of a solid-tip 4 mm non-irrigated catheter in focal-bipolar PFA create lesions with greater depth, volume and diameter compared to an open-irrigated flexible-tip catheter. Ablation catheter type significantly influences lesion spread during focal-bipolar PFA.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.191
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of catheter type on lesion dimensions in focal-bipolar pulsed field ablation

Agata Wawrzyniak, P Futyma, Łukasz Zarębski
EP Europace
Laser-induced spectroscopy and plasma
article

Impact of catheter type on lesion dimensions in focal-bipolar pulsed field ablation

Agata Wawrzyniak, P Futyma, Łukasz Zarębski
article en

Abstract

Abstract Introduction Pulsed field ablation (PFA) is a novel technique for pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF). However, the impact of electrode type on lesion formation at fixed PFA parameters remains unknown. This study investigated differences in lesion characteristics when using a 4 mm non-irrigated catheter versus an open-irrigated flexible-tip catheter in focal-bipolar PFA in a vegetable model. Methods PFA applications were performed in a potato model using a purpose-made PFA generator, applying both a solid-tip 4 mm non-irrigated catheter and an open-irrigated flexible-tip catheter under identical energy delivery parameters. After electroporation, potatoes were stained with triphenyltetrazolium chloride (TTC) to visualize lesion boundaries. Depth, diameter, and volume of the irreversibly electroporated zones were measured to assess the impact of each electrode type. Results A total of fifty PFA applications were performed—25 with the 4 mm non-irrigated catheter and 25 with the open-irrigated flexible-tip catheter. The depth of the irreversible electroporation zone was significantly greater with the 4 mm non-irrigated catheter than with the irrigated electrode (1.7±0.5 mm vs. 1.4±0.7 mm, p=0.03). The diameter of irreversible lesions created with the 4 mm electrode was 7±1 mm, compared to 6±1 mm with the irrigated electrode (p=0.001), resulting in a total lesion volume of 185 mm³ versus 120 mm³, respectively (p=0.0008). Conclusion The use of a solid-tip 4 mm non-irrigated catheter in focal-bipolar PFA create lesions with greater depth, volume and diameter compared to an open-irrigated flexible-tip catheter. Ablation catheter type significantly influences lesion spread during focal-bipolar PFA.

EP EuropaceVol. 27(Supplement_1)
University of Rzeszów (PL)
Openalex Percentile: Top 88%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of catheter type on lesion dimensions in focal-bipolar pulsed field ablation — Agata Wawrzyniak, P Futyma, et al. · EP Europace (2025) | TGRS Research Map | TGRS