Initial experience of electroanatomic mapping guided pulsed field ablation for atrial fibrillation ablation in patients with hypertrophic cardiomyopathy

Abstract Background Freedom from atrial arrhythmia recurrence after pulmonary vein isolation (PVI) in patients with hypertrophic cardiomyopathy (HCM) remains a major challenge. Aims To report a high-volume single center initial experience on safety and effectivity of pulsed field ablation (PFA) in patients with HCM. Methods Consecutive patients with HCM undergoing first time PVI by PFA between 02/2022 and 11/2024 were prospectively enrolled. A cohort of patients without HCM undergoing PFA served as control group. Ablation was performed using a commercially available PFA system comprising a generator, a 13.8 Fr steerable sheath and a 12 Fr over-the-wire ablation device with seamless changing between a "flower-like" and a "basket-like" pose. Electroanatomic mapping using a 3D-system and a spiral mapping catheter were performed in each patient before PFA. The general ablation protocol provided 8 PFA impulses for each pulmonary vein (PV) with 4 impulses in the basket-like shape of the device and 4 impulses in the flower-like shape. In cases of failed PV isolation another complete cycle of 8 impulses per vein was delivered. A pre- and post-ablation electroanatomic map was performed in every patient. In patients with posterior wall low voltage areas, impulses were delivered aiming at posterior wall isolation (PWI). The procedural endpoint was complete PVI with demonstration of entrance and exit block of all PVs and isolation of the posterior wall if attempted. Results The study group consisted of 23 patients (43.5% males, mean age 56.7±7.8 years) with HCM. Persistent AF was present in 8 patients (34.8%). Mean left ventricular ejection fraction was 56.3±7.8%, mean end diastolic interventricular septum diameter 20.1±2.5 mm and mean left atrial volume index 59.9±17.9 ml/m². 23 patients without HCM were matched. Mean procedural duration for the study group was 58.1±4.5 minutes with a mean fluoroscopy time of 9.5±3.0 minutes. Four patients (17.4%) showed incomplete PV isolation during remapping and underwent repeat PFA. Five patients (21.7%) showed low-voltage at the posterior wall during 3D sinus-rhythm mapping and underwent PWI with 14.7±11 impulses. Mean number of total impulses per patient was 45.8±16.1 in the study group. In the control group, procedural duration was 49.3±2.5 min (p=0.1) with a significant lower number of ablation impulses per patient as compared to the study group (33.5±5.3, p=0.01). No periprocedural complications occurred. Four patients (17.4%) experienced recurrent persistent AF during follow-up of 365.7±62.4 days in the study group, which was comparable to 2 patients (8.7%) with arrhythmia recurrence in the control group (p=0.76). Conclusions 3D-guided PFA in HCM patients is associated with high acute success rates. Mid-term follow-up showed modest arrhythmia recurrence rates. However, larger trials with longer follow-up periods are necessary in this challenging patient cohort.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.477
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial experience of electroanatomic mapping guided pulsed field ablation for atrial fibrillation ablation in patients with hypertrophic cardiomyopathy

Moneeb Khalaph, P Sommer, Christian Sohns, Martin Braun et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Initial experience of electroanatomic mapping guided pulsed field ablation for atrial fibrillation ablation in patients with hypertrophic cardiomyopathy

Moneeb Khalaph, P Sommer, Christian Sohns, Martin Braun, Thomas Fink, Maximilian Moersdorf, Vanessa Sciacca, Guram Imnadze, Mustapha El Hamriti, Denise Guckel, S. V. Voitenko
article en

Abstract

Abstract Background Freedom from atrial arrhythmia recurrence after pulmonary vein isolation (PVI) in patients with hypertrophic cardiomyopathy (HCM) remains a major challenge. Aims To report a high-volume single center initial experience on safety and effectivity of pulsed field ablation (PFA) in patients with HCM. Methods Consecutive patients with HCM undergoing first time PVI by PFA between 02/2022 and 11/2024 were prospectively enrolled. A cohort of patients without HCM undergoing PFA served as control group. Ablation was performed using a commercially available PFA system comprising a generator, a 13.8 Fr steerable sheath and a 12 Fr over-the-wire ablation device with seamless changing between a "flower-like" and a "basket-like" pose. Electroanatomic mapping using a 3D-system and a spiral mapping catheter were performed in each patient before PFA. The general ablation protocol provided 8 PFA impulses for each pulmonary vein (PV) with 4 impulses in the basket-like shape of the device and 4 impulses in the flower-like shape. In cases of failed PV isolation another complete cycle of 8 impulses per vein was delivered. A pre- and post-ablation electroanatomic map was performed in every patient. In patients with posterior wall low voltage areas, impulses were delivered aiming at posterior wall isolation (PWI). The procedural endpoint was complete PVI with demonstration of entrance and exit block of all PVs and isolation of the posterior wall if attempted. Results The study group consisted of 23 patients (43.5% males, mean age 56.7±7.8 years) with HCM. Persistent AF was present in 8 patients (34.8%). Mean left ventricular ejection fraction was 56.3±7.8%, mean end diastolic interventricular septum diameter 20.1±2.5 mm and mean left atrial volume index 59.9±17.9 ml/m². 23 patients without HCM were matched. Mean procedural duration for the study group was 58.1±4.5 minutes with a mean fluoroscopy time of 9.5±3.0 minutes. Four patients (17.4%) showed incomplete PV isolation during remapping and underwent repeat PFA. Five patients (21.7%) showed low-voltage at the posterior wall during 3D sinus-rhythm mapping and underwent PWI with 14.7±11 impulses. Mean number of total impulses per patient was 45.8±16.1 in the study group. In the control group, procedural duration was 49.3±2.5 min (p=0.1) with a significant lower number of ablation impulses per patient as compared to the study group (33.5±5.3, p=0.01). No periprocedural complications occurred. Four patients (17.4%) experienced recurrent persistent AF during follow-up of 365.7±62.4 days in the study group, which was comparable to 2 patients (8.7%) with arrhythmia recurrence in the control group (p=0.76). Conclusions 3D-guided PFA in HCM patients is associated with high acute success rates. Mid-term follow-up showed modest arrhythmia recurrence rates. However, larger trials with longer follow-up periods are necessary in this challenging patient cohort.

EP EuropaceVol. 27(Supplement_1)
Heart and Diabetes Center North Rhine-Westphalia (DE)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.