Local multifrequency impedance to characterize RF ablations

Abstract Introduction Radiofrequency (RF) ablation is one of the principal treatments of cardiac arrhythmias. The electroanatomical systems used to perform RF ablations use specific metrics to approximate the ablation lesion size, but these indicators are based on ablation parameters (catheter pressure, ablation time, and power) and ignore the local characteristics of the tissue. Local multifrequency impedance magnitude (LMI) may overcome these limitations. Purpose The objective of this study was to characterize the changes in LMI magnitude after performing ablations with different powers in the epicardium of anesthetized pigs. Methods Lesions were performed on the epicardium of the left ventricle in 9 anesthetized pigs while measuring LMI (from 1 to 173 kHz) before, during, and after ablations (20W/30W/40W, 60s, >10g) through a conventional irrigated electrocatheter connected to a cardiac navigation system and a RF generator. In a subset of measurements, the myocardial temperature was recorded using an optical fiber inserted into the epicardium. Local voltage (Vuni) was also measured before and after ablations, and catheter-measured temperature and contact force were monitored. At the end of the procedure, the animals were sacrificed, and a histological study of the lesions was performed. The study followed the "Principles of laboratory animal care" (NIH Publication no. 85-23 revised 1985) and was reviewed and approved by the Institutional Animal Care and Use Committee of our Institution. Results A total of thirty-two effective ablations were performed. In 11 of those we also measured the tissue temperature. The 40W lesions were deeper and wider than the rest (Fig 1. ANOVA: p<0.01). The changes in the LMI at high frequencies during the ablation correlated well with the changes in tissue temperature (Fig 2. 20W: LMI magnitude @ 173kHz vs. Tissue temperature, r2=0.62; p<0.01). The LMI of 40W lesions decreased faster and to a lower value during the first five seconds of ablation (p<0.05). After thermal adjustment, LMI recorded 30 and 55 seconds after the start of the ablation correlated better with the final depth of the lesion than generator impedance or local voltage (Fig 2). Conclusions The measure of LMI during ablation allows a better quantification of the changes in the structural characteristics of myocardial tissue than the generator impedance. The increase in tissue temperature during ablation influences the values of local impedance and should be adjusted to correctly predict the chronic size of the RF lesion.Fig. 1RF lesion sizes Fig. 2LMI vs temp and time

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.077
Primary Topic
Electrostatic Discharge in Electronics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local multifrequency impedance to characterize RF ablations

María José Guerra Palmero, J. Rosell, R. Bragós, S Casabella-Ramon et al.
EP Europace
Electrostatic Discharge in Electronics
article

Local multifrequency impedance to characterize RF ablations

María José Guerra Palmero, J. Rosell, R. Bragós, S Casabella-Ramon, Gerard Amorós-Figueras, Zoraida Moreno‐Weidmann, M Soriano-Amores
article en

Abstract

Abstract Introduction Radiofrequency (RF) ablation is one of the principal treatments of cardiac arrhythmias. The electroanatomical systems used to perform RF ablations use specific metrics to approximate the ablation lesion size, but these indicators are based on ablation parameters (catheter pressure, ablation time, and power) and ignore the local characteristics of the tissue. Local multifrequency impedance magnitude (LMI) may overcome these limitations. Purpose The objective of this study was to characterize the changes in LMI magnitude after performing ablations with different powers in the epicardium of anesthetized pigs. Methods Lesions were performed on the epicardium of the left ventricle in 9 anesthetized pigs while measuring LMI (from 1 to 173 kHz) before, during, and after ablations (20W/30W/40W, 60s, >10g) through a conventional irrigated electrocatheter connected to a cardiac navigation system and a RF generator. In a subset of measurements, the myocardial temperature was recorded using an optical fiber inserted into the epicardium. Local voltage (Vuni) was also measured before and after ablations, and catheter-measured temperature and contact force were monitored. At the end of the procedure, the animals were sacrificed, and a histological study of the lesions was performed. The study followed the "Principles of laboratory animal care" (NIH Publication no. 85-23 revised 1985) and was reviewed and approved by the Institutional Animal Care and Use Committee of our Institution. Results A total of thirty-two effective ablations were performed. In 11 of those we also measured the tissue temperature. The 40W lesions were deeper and wider than the rest (Fig 1. ANOVA: p<0.01). The changes in the LMI at high frequencies during the ablation correlated well with the changes in tissue temperature (Fig 2. 20W: LMI magnitude @ 173kHz vs. Tissue temperature, r2=0.62; p<0.01). The LMI of 40W lesions decreased faster and to a lower value during the first five seconds of ablation (p<0.05). After thermal adjustment, LMI recorded 30 and 55 seconds after the start of the ablation correlated better with the final depth of the lesion than generator impedance or local voltage (Fig 2). Conclusions The measure of LMI during ablation allows a better quantification of the changes in the structural characteristics of myocardial tissue than the generator impedance. The increase in tissue temperature during ablation influences the values of local impedance and should be adjusted to correctly predict the chronic size of the RF lesion.Fig. 1RF lesion sizes Fig. 2LMI vs temp and time

EP EuropaceVol. 27(Supplement_1)
Hospital de Sant Pau (ES), Centro de Investigación en Red en Enfermedades Cardiovasculares (ES), Universitat Politècnica de Catalunya (ES)
Centro de Investigación Biomédica en Red Enfermedades Cardiovasculares, Instituto de Salud Carlos III
Openalex Percentile: Top 91%
Electrostatic Discharge in Electronics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.