Clinical validation of in-silico pace-mapping for non-invasive guidance in ablation planning

Abstract Background In-silico pace-mapping uses a patient-specific computational model alongside the patient’s ECG to generate a 'virtual' fully 3D pace map for guiding ablation therapy. Whilst a promising pre-procedural tool to optimize treatment, its clinical effectiveness remains to be validated through further clinical data. Purpose To assess the ability of in-silico pace-mapping in identifying the site of focal origin during clinical pacing. Methods High-resolution contrast computer tomography (CT) and late enhancement cardiac wideband MRI of three patients were obtained pre-ablation procedure and used to construct personalized torso-ventricular computational models (Fig. A). Infarct anatomy (scar and border zone) was obtained either from commercially available segmentation software (ADAS3D) (n=2) or voltage data and mapped onto the torso-ventricular models (n=1) (Fig. B). ECGs from body-surface locations (Fig. C) were obtained during pace mapping procedure, and their respective pacing sites (N~16 per patient) exported from the mapping system (CARTO, Biosense Webster) and used as ground truth. In-silico pace-mapping involved pacing the heart at 1000 random sites on the surface of the left ventricle and computing respective ECGs. Location of ECG electrodes on the patient’s torso was inferred through registered fluoroscopy images to ensure close match. Correlation analysis compared clinically-acquired and simulated ECGs for each of the 1000 pacing sites, constructing virtual pace maps (Fig. D). The average of the top 10 coefficients across leads (ccm10) was calculated. The distance (d) between the pacing electrode and the location with the strongest correlation was determined (Fig. D). The median and interquartile range of d across all patients and pacing locations (N=51) was calculated. Results Fig. D presents the pace map obtained for one patient paced a representative location (blue star). The strongest correlation point (ccm10=0.716) is marked by a red star with a distance to the ground-truth (blue star) of 7.5mm. The median distance for this patient across all N=12 pacing sites was d = 13.7mm (IQR: 11.0-27.6) compared to d = 24mm (IQR: 16.1-28.4, N=18) and d = 43mm (IQR: 24.2-53.5, N=21) for the other two patients. The spatial precision across all patients (N=51), shown in Fig. E, was 26.6mm (IQR: 16.4-16.4). Conclusion This work demonstrated the value of in-silico pace mapping in determining the origin of ventricular pacing in patient-specific ventricular-torso models, offering a rapid, risk-free pre-procedure testbed. However, further validation on a larger patient cohort is necessary to enhance robustness and broaden clinical applicability.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.743
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical validation of in-silico pace-mapping for non-invasive guidance in ablation planning

Gernot Plank, Aurel Neic, Christopher A. Rinaldi, Fernando O. Campos et al.
EP Europace
Intraocular Surgery and Lenses
article

Clinical validation of in-silico pace-mapping for non-invasive guidance in ablation planning

Gernot Plank, Aurel Neic, Christopher A. Rinaldi, Fernando O. Campos, Martin J. Bishop, Anila Rashid, Luca Azzolin, Pranav Bhagirath, Urs Rohrer, J C Burger, John Whitaker, L Nazarov
article en

Abstract

Abstract Background In-silico pace-mapping uses a patient-specific computational model alongside the patient’s ECG to generate a 'virtual' fully 3D pace map for guiding ablation therapy. Whilst a promising pre-procedural tool to optimize treatment, its clinical effectiveness remains to be validated through further clinical data. Purpose To assess the ability of in-silico pace-mapping in identifying the site of focal origin during clinical pacing. Methods High-resolution contrast computer tomography (CT) and late enhancement cardiac wideband MRI of three patients were obtained pre-ablation procedure and used to construct personalized torso-ventricular computational models (Fig. A). Infarct anatomy (scar and border zone) was obtained either from commercially available segmentation software (ADAS3D) (n=2) or voltage data and mapped onto the torso-ventricular models (n=1) (Fig. B). ECGs from body-surface locations (Fig. C) were obtained during pace mapping procedure, and their respective pacing sites (N~16 per patient) exported from the mapping system (CARTO, Biosense Webster) and used as ground truth. In-silico pace-mapping involved pacing the heart at 1000 random sites on the surface of the left ventricle and computing respective ECGs. Location of ECG electrodes on the patient’s torso was inferred through registered fluoroscopy images to ensure close match. Correlation analysis compared clinically-acquired and simulated ECGs for each of the 1000 pacing sites, constructing virtual pace maps (Fig. D). The average of the top 10 coefficients across leads (ccm10) was calculated. The distance (d) between the pacing electrode and the location with the strongest correlation was determined (Fig. D). The median and interquartile range of d across all patients and pacing locations (N=51) was calculated. Results Fig. D presents the pace map obtained for one patient paced a representative location (blue star). The strongest correlation point (ccm10=0.716) is marked by a red star with a distance to the ground-truth (blue star) of 7.5mm. The median distance for this patient across all N=12 pacing sites was d = 13.7mm (IQR: 11.0-27.6) compared to d = 24mm (IQR: 16.1-28.4, N=18) and d = 43mm (IQR: 24.2-53.5, N=21) for the other two patients. The spatial precision across all patients (N=51), shown in Fig. E, was 26.6mm (IQR: 16.4-16.4). Conclusion This work demonstrated the value of in-silico pace mapping in determining the origin of ventricular pacing in patient-specific ventricular-torso models, offering a rapid, risk-free pre-procedure testbed. However, further validation on a larger patient cohort is necessary to enhance robustness and broaden clinical applicability.

EP EuropaceVol. 27(Supplement_1)
King's College London (GB), Medical University of Graz (AT), Numerica Corporation (United States) (US)
British Heart Foundation
Openalex Percentile: Top 81%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.