Effect of axillary vein access versus cephalic access and subclavian puncture on ICD lead performance during long-term follow-up

Abstract Introduction Defibrillation lead failure is a typical long-term complication of implantable cardioverter defibrillator (ICD) therapy. ICD shock leads which are inserted by puncturing the subclavian vein, are susceptible to lead failure. Alternative transvenous accesses are the cephalic cutdown or the axillary venous access. The aim of the study was to assess the effect of different insertion techniques on the rate of defects in transvenous defibrillation leads during long-term follow-up. Methods A total of 1440 consecutive ICD patients from a prospective single-centre ICD-registry who underwent first ICD implantation between 2008 and 9/2023 were analyzed. Implantation of ICD lead via subclavian puncture was performed from 2008 to 2023, via cephalic access from 2015 to 2020 and via an axillary venous access since 2018. All patients received an ICD lead insulated with silicone-polyurethane. Results Baseline characteristics were similar in all groups in terms of age, gender and EF (Table 1). The estimated lead survival rate after 5 years was 96% in the axillary group, 94% in the cephalic group and 89% in the subclavian group (Figure 1). Conclusion The rate of defects in ICD leads implanted via axillary venous access was similar to those implanted by cephalic access, whereas insertion via subclavian puncture was associated with a higher ICD lead defect during long-term follow-up. Figure 1

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.589
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of axillary vein access versus cephalic access and subclavian puncture on ICD lead performance during long-term follow-up

A Wenz, Alev Oeztuerk, Mariana Strauss, U Weisse et al.
1 links
EP Europace
Cardiac Arrhythmias and Treatments
article

Effect of axillary vein access versus cephalic access and subclavian puncture on ICD lead performance during long-term follow-up

A Wenz, Alev Oeztuerk, Mariana Strauss, U Weisse, Christiane Werling, Thomas Kleemann, R. Zahn, K Kouraki, Falk‐Udo Sack
article en

Abstract

Abstract Introduction Defibrillation lead failure is a typical long-term complication of implantable cardioverter defibrillator (ICD) therapy. ICD shock leads which are inserted by puncturing the subclavian vein, are susceptible to lead failure. Alternative transvenous accesses are the cephalic cutdown or the axillary venous access. The aim of the study was to assess the effect of different insertion techniques on the rate of defects in transvenous defibrillation leads during long-term follow-up. Methods A total of 1440 consecutive ICD patients from a prospective single-centre ICD-registry who underwent first ICD implantation between 2008 and 9/2023 were analyzed. Implantation of ICD lead via subclavian puncture was performed from 2008 to 2023, via cephalic access from 2015 to 2020 and via an axillary venous access since 2018. All patients received an ICD lead insulated with silicone-polyurethane. Results Baseline characteristics were similar in all groups in terms of age, gender and EF (Table 1). The estimated lead survival rate after 5 years was 96% in the axillary group, 94% in the cephalic group and 89% in the subclavian group (Figure 1). Conclusion The rate of defects in ICD leads implanted via axillary venous access was similar to those implanted by cephalic access, whereas insertion via subclavian puncture was associated with a higher ICD lead defect during long-term follow-up. Figure 1

EP EuropaceVol. 27(Supplement_1)
Klinikum Ludwigshafen (DE)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.