Incidence and predictors of successful lead extraction with short active mechanical extraction sheaths only

Abstract Background and aims Transvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices. Active mechanical rotational sheaths facilitate extraction and are available in short and long sizes. This study aimed to evaluate the incidence and predictors of successful TLE using only short active mechanical sheaths. Methods We retrospectively analysed patients who underwent TLE at a single centre from 2013 until 2023 regarding clinical and radiological success and complications. Results 556 patients underwent 568 TLE from January 2013 until December 2023. 55 (9.7%) TLE were successful using only short mechanical sheaths. Predictors for successful TLE using only short sheaths in multivariate analysis were lead dwell time (OR 0.98, CI 0.97 – 0.99, p < 0.001) and anticoagulation (OR 0.60, CI 0.34 – 1.08, p < 0.05). Major complications occurred in 4.8% of TLE with a numerically lower rate when only short sheaths were used (3.6%). Conclusion Short active rotational mechanical sheaths are sufficient for successful TLE in 10% of patients. Anticoagulation and lead dwell time are independent predictors of successful TLE with short active extraction sheaths only.Baseline characteristics Predictors of successful extraction

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.638
Primary Topic
Extraction and Separation Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incidence and predictors of successful lead extraction with short active mechanical extraction sheaths only

Alexander Breitenstein, Jan Steffel, C Wiederkehr, Andreas Haeberlin et al.
EP Europace
Extraction and Separation Processes
article

Incidence and predictors of successful lead extraction with short active mechanical extraction sheaths only

Alexander Breitenstein, Jan Steffel, C Wiederkehr, Andreas Haeberlin, Daniel Höfer
article en

Abstract

Abstract Background and aims Transvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices. Active mechanical rotational sheaths facilitate extraction and are available in short and long sizes. This study aimed to evaluate the incidence and predictors of successful TLE using only short active mechanical sheaths. Methods We retrospectively analysed patients who underwent TLE at a single centre from 2013 until 2023 regarding clinical and radiological success and complications. Results 556 patients underwent 568 TLE from January 2013 until December 2023. 55 (9.7%) TLE were successful using only short mechanical sheaths. Predictors for successful TLE using only short sheaths in multivariate analysis were lead dwell time (OR 0.98, CI 0.97 – 0.99, p < 0.001) and anticoagulation (OR 0.60, CI 0.34 – 1.08, p < 0.05). Major complications occurred in 4.8% of TLE with a numerically lower rate when only short sheaths were used (3.6%). Conclusion Short active rotational mechanical sheaths are sufficient for successful TLE in 10% of patients. Anticoagulation and lead dwell time are independent predictors of successful TLE with short active extraction sheaths only.Baseline characteristics Predictors of successful extraction

EP EuropaceVol. 27(Supplement_1)
University Hospital of Bern (CH), University Hospital of Zurich (CH)
Openalex Percentile: Top 89%
Extraction and Separation Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Incidence and predictors of successful lead extraction with short active mechanical extraction sheaths only — Alexander Breitenstein, Jan Steffel, et al. · EP Europace (2025) | TGRS Research Map | TGRS