A novel method for phrenic nerve monitoring during cryo-balloon procedures

Abstract Background Cryo-balloon ablation is associated with a consistent risk of phrenic nerve damage. Currently, only the diaphragmatic compound motor action potential (CMAP) has been shown to be effective in preventing this complication. Purpose evaluate the diagnostic performance of a new surface electrodes positioning, named NeedMAP, using CMAP as the gold standard. Methods 150 patients underwent cryo-balloon ablation. During the procedure we placed the CMAP leads as per manufacturer indication and our alternative method by placing ECG electrodes on the anterior axillary line. We simultaneously recorded the CMAP and the NeedMAP. Results A total of 438 cryo-balloon applications were performed on the right pulmonary veins. The mean value of CMAP amplitudes were 0.60±0.33mV, whereas the NeedMAP were 0.85±0.46mV (p < 0.001). 15 patients (10%) showed a nerve threat. We found that in our population the CMAP, on regards of nerve damages, had a sensitivity of 38% and specificity of 76%. The NeedMAP showed a sensitivity of 61% and specificity of 86%. Conclusion The NeedMAP signals for PN monitoring during cryo-balloon ablation seems a reliable method, showing good sensitivity, specificity and can help clinician for preventing phrenic nerve damage.Figure 1 Figure 2

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.326
Primary Topic
Thermal Expansion and Ionic Conductivity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for phrenic nerve monitoring during cryo-balloon procedures

Stefano Bonapace, Konstantinos Trachanas, F Cecchini, Alessio Marinelli et al.
EP Europace
Thermal Expansion and Ionic Conductivity
article

A novel method for phrenic nerve monitoring during cryo-balloon procedures

Stefano Bonapace, Konstantinos Trachanas, F Cecchini, Alessio Marinelli, Maurizio Corso, Alessandro Mantovani, Alessandro Costa, Giulio Molon, Davide Fasoli, Michele Canton
article en

Abstract

Abstract Background Cryo-balloon ablation is associated with a consistent risk of phrenic nerve damage. Currently, only the diaphragmatic compound motor action potential (CMAP) has been shown to be effective in preventing this complication. Purpose evaluate the diagnostic performance of a new surface electrodes positioning, named NeedMAP, using CMAP as the gold standard. Methods 150 patients underwent cryo-balloon ablation. During the procedure we placed the CMAP leads as per manufacturer indication and our alternative method by placing ECG electrodes on the anterior axillary line. We simultaneously recorded the CMAP and the NeedMAP. Results A total of 438 cryo-balloon applications were performed on the right pulmonary veins. The mean value of CMAP amplitudes were 0.60±0.33mV, whereas the NeedMAP were 0.85±0.46mV (p < 0.001). 15 patients (10%) showed a nerve threat. We found that in our population the CMAP, on regards of nerve damages, had a sensitivity of 38% and specificity of 76%. The NeedMAP showed a sensitivity of 61% and specificity of 86%. Conclusion The NeedMAP signals for PN monitoring during cryo-balloon ablation seems a reliable method, showing good sensitivity, specificity and can help clinician for preventing phrenic nerve damage.Figure 1 Figure 2

EP EuropaceVol. 27(Supplement_1)
Ospedale Sacro Cuore Don Calabria (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Openalex Percentile: Top 92%
Thermal Expansion and Ionic Conductivity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel method for phrenic nerve monitoring during cryo-balloon procedures — Stefano Bonapace, Konstantinos Trachanas, et al. · EP Europace (2025) | TGRS Research Map | TGRS